BACK-UP LIGHT SWITCH INSPECTION


  1. INSPECT BACK-UP LIGHT SWITCH ASSEMBLY


    1. A01DXTHE01

      Measure the resistance of the switch.

      Standard:
      Tester Connection Switch Condition Specified Condition
      1 - 2 Pushed Below 1 Ω
      1 - 2 Not Pushed 10 kΩ or higher

      If the result is not as specified, replace the switch assembly.