RELAY ON-VEHICLE INSPECTION

PROCEDURE

  1. INSPECT HEADLIGHT RELAY (H-LP LO)

    1. E277745E02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Battery voltage not applied to terminals 1 and 2

      10 kΩ or higher

      Battery voltage applied to terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the headlight relay.

  2. INSPECT HEADLIGHT RELAY (H-LP HI)

    1. E277745E02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Battery voltage not applied to terminals 1 and 2

      10 kΩ or higher

      Battery voltage applied to terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the headlight relay.

  3. INSPECT NO. 1 DAY TIME RUNNING LIGHT RELAY (DRL)

    1. E277744E01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Battery voltage not applied to terminals 1 and 2

      10 kΩ or higher

      Battery voltage applied to terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the No. 1 day time running light relay.

  4. INSPECT REAR FOG LIGHT RELAY (FOG RR)

    1. E277744N02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Battery voltage not applied to terminals 1 and 2

      10 kΩ or higher

      Battery voltage applied to terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the rear fog light relay.

  5. INSPECT BACK UP LIGHT RELAY (BKUP LP No. 2)

    1. E277744E01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Battery voltage not applied to terminals 1 and 2

      10 kΩ or higher

      Battery voltage applied to terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the back up light relay.