FUEL SUPPLY PUMP INSPECTION

PROCEDURE

  1. INSPECT FUEL SUPPLY PUMP ASSEMBLY

    1. Inspect the fuel quantity control valve.

      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        1 - 2

        20°C (68°F)

        2.6 to 3.2 Ω

        If the result is not as specified, replace the fuel supply pump assembly.