FUEL SUPPLY PUMP INSPECTION
PROCEDURE
INSPECT FUEL SUPPLY PUMP ASSEMBLY
Inspect the fuel quantity control valve.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
2.6 to 3.2 Ω
If the result is not as specified, replace the fuel supply pump assembly.