ПОДОГРЕВАЕМЫЙ КИСЛОРОДНЫЙ ДАТЧИК УСТАНОВКА


  1. INSTALL HEATED OXYGEN SENSOR


    1. A01E29UE01

      Using SST, install the sensor.

      SST
      09224-00010
      Torque:
      44 N*m  { 449 kgf*cm, 32 ft.*lbf, for use without SST }
      40 N*m  { 408 kgf*cm, 30 ft.*lbf, for use with SST }

      Tech Tips

      Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).

    2. A01DX86

      Attach the 3 wire clamps to the vehicle body.

    3. Connect the sensor connector.

  2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

  3. PERFORM INITIALIZATION


    1. Perform initialization Click here.

      CAUTION:

      Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.