CAN COMMUNICATION SYSTEM ECM Communication Stop Mode
| DTC Code | DTC Name |
|---|---|
| ECM Communication Stop Mode |
DESCRIPTION
Detection Item |
Symptom |
Trouble Area |
|---|---|---|
ECM Communication Stop Mode |
Either condition is met:
|
|
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output (Click here).
Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key, switches or opening or closing the doors. After that, disconnect the cable from the negative (-) battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.
After the repair, perform CAN Bus Check and check that all the ECUs and sensors connected to the CAN communication system are displayed (Click here).
Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.
PROCEDURE
CHECK FOR OPEN IN CAN BUS WIRE (ECM CAN MAIN WIRE)
-
Disconnect the cable from the negative (-) battery terminal.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 1. for 1ZR-FAE, 2ZR-FAE Tester Connection
Condition
Specified Condition
A76-13 (CANH) - A76-26 (CANL)
Cable disconnected from negative (-) battery terminal
108 to 132 Ω
Table 2. for 1WW Tester Connection
Condition
Specified Condition
A76-26 (CANH) - A76-25 (CANL)
Cable disconnected from negative (-) battery terminal
108 to 132 Ω
Table 3. Text in Illustration *A
for 1ZR-FAE, 2ZR-FAE
*B
for 1WW
*a
Front view of wire harness connector
(to ECM)
REPAIR OR REPLACE CAN MAIN WIRE CONNECTED TO ECM (CANH, CANL)
-
CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND)
Connect the cable to the negative (-) battery terminal.
Note:When connecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
for 1ZR-FAE, 2ZR-FAE:
Table 4. Text in Illustration *a
Front view of wire harness connector
(to ECM)
-
-
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
A76-32 (EC) - Body ground
Always
Below 1 Ω
C111-26 (E04) - Body ground
Always
Below 1 Ω
C111-28 (ME01) - Body ground
Always
Below 1 Ω
C111-57 (E01) - Body ground
Always
Below 1 Ω
C111-58 (E02) - Body ground
Always
Below 1 Ω
C111-59 (E1) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
C111-29 (+BM) - Body ground
Always
11 to 14 V
A76-1 (BATT) - Body ground
Always
11 to 14 V
A76-3 (+B2) - Body ground
Battery positive (+) voltage applied to terminal A76-46 (MREL)
11 to 14 V
A76-2 (+B) - Body ground
Battery positive (+) voltage applied to terminal A76-46 (MREL)
11 to 14 V
for 1WW:
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
A76-4 (E1) - Body ground
Always
Below 1 Ω
A76-5 (E2) - Body ground
Always
Below 1 Ω
A76-17 (E3) - Body ground
Always
Below 1 Ω
A76-18 (E4) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
A76-15 (BATT) - Body ground
Always
11 to 14 V
A76-1 (+B3) - Body ground
Battery positive (+) voltage applied to terminal A76-9 (MREL)
11 to 14 V
A76-14 (+B2) - Body ground
Battery positive (+) voltage applied to terminal A76-9 (MREL)
11 to 14 V
A76-2 (+B) - Body ground
Battery positive (+) voltage applied to terminal A76-9 (MREL)
11 to 14 V
Table 5. Text in Illustration *a
Front view of wire harness connector
(to ECM)
-
Table 6. Result Result
Proceed to
OK (for 1ZR-FAE)
A
OK (for 2ZR-FAE)
B
OK (for 1WW)
C
NG
D
REPAIR OR REPLACE HARNESS OR CONNECTOR