RELAY ON-VEHICLE INSPECTION
PROCEDURE
INSPECT NO. 1 INTEGRATION RELAY (IG2)
Measure the resistance of the IG2 fuse.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
IG2 Fuse
Always
Below 1 Ω
If the result is not as specified, replace the IG2 fuse.
-
Measure the resistance of the IG2 relay.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1C-1 - 1A-4
Battery voltage not applied to terminals 1A-2 and 1A-3
10 kΩ or higher
1C-1 - 1A-4
Battery voltage applied to terminals 1A-2 and 1A-3
Below 1 Ω
Table 1. Text in Illustration *a
Component without harness connected
(No. 1 Integration Relay)
If the result is not as specified, replace the No. 1 integration relay.
INSPECT NO. 1 INTEGRATION RELAY (FUEL PUMP)
Measure the resistance of the FUEL PUMP fuse.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
FUEL PUMP Fuse
Always
Below 1 Ω
If the result is not as specified, replace the FUEL PUMP fuse.
-
Measure the resistance of the FUEL PUMP relay.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1C-1 - 1B-4
Battery voltage not applied to terminals 1B-2 and 1B-3
10 kΩ or higher
1C-1 - 1B-4
Battery voltage applied to terminals 1B-2 and 1B-3
Below 1 Ω
Table 2. Text in Illustration *a
Component without harness connected
(No. 1 Integration Relay)
If the result is not as specified, replace the No. 1 integration relay.
INSPECT EFI MAIN RELAY (EFI MAIN)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
3 - 5
Battery voltage applied to terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the EFI MAIN relay.
INSPECT FUEL FILTER RELAY (FUEL FILTER)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied to terminals 1 and 2
10 kΩ or higher
3 - 5
Battery voltage applied to terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the FUEL FILTER relay.