VACUUM SWITCHING VALVE(for ACIS) INSTALLATION
PROCEDURE
INSTALL VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
Install the bracket to the vacuum switching valve assembly (for ACIS) with the screw.
3.3 N*m
34 kgf*cm
29 in.*lbf
Install the vacuum switching valve assembly (for ACIS) to the intake manifold with the bolt.
10 N*m
102 kgf*cm
7 ft.*lbf
Connect the No. 2 air hose and vacuum hose to the vacuum switching valve assembly (for ACIS).
Connect the connector to the vacuum switching valve assembly (for ACIS).
INSTALL NO. 2 CYLINDER HEAD COVER