VACUUM SWITCHING VALVE(for ACIS) INSTALLATION

PROCEDURE

  1. INSTALL VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)

    1. Install the bracket to the vacuum switching valve assembly (for ACIS) with the screw.

      3.3 N*m

      34 kgf*cm

      29 in.*lbf

    2. Install the vacuum switching valve assembly (for ACIS) to the intake manifold with the bolt.

      10 N*m

      102 kgf*cm

      7 ft.*lbf

    3. Connect the No. 2 air hose and vacuum hose to the vacuum switching valve assembly (for ACIS).

    4. Connect the connector to the vacuum switching valve assembly (for ACIS).

  2. INSTALL NO. 2 CYLINDER HEAD COVER