METER / GAUGE SYSTEM Entire Combination Meter does not Operate
| DTC Code | DTC Name |
|---|---|
| Entire Combination Meter does not Operate |
DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is turned to ON, the combination meter does not operate.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses of circuits related to this system before performing the following procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
-
Disconnect the combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
H62-21 (ET) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
H62-40 (B) - Body ground
Always
11 to 14 V
Table 1. Text in Illustration *a
Rear view of wire harness connector
(to Combination Meter Assembly)
REPAIR OR REPLACE HARNESS OR CONNECTOR
-
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY)
-
Disconnect the combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Switch Condition
Specified Condition
H62-39 (IG+) - Body ground
Ignition switch ON
11 to 14 V
Table 2. Text in Illustration *a
Rear view of wire harness connector
(to Combination Meter Assembly)
-
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - ENGINE STOP AND START ECU)
Disconnect the H62 combination meter assembly connector.
Disconnect the H121 engine stop and start ECU connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
H62-39 (IG+) - H121-1 (IG02)
Always
Below 1 Ω
H62-39 (IG+) or H121-1 (IG02) - Body ground
Always
10 kΩ or higher
REPAIR OR REPLACE HARNESS OR CONNECTOR