AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) DATA LIST / ACTIVE TEST

  1. DATA LIST

    Tip:

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Read the Data List according to the display on the GTS.

      Body Electrical > Air Conditioner > Data List

      Tester Display

      Range

      Peak_CPU

      Min.: 0

      Max.: 100

      Instantaneous CPU load

      Min.: 0

      Max.: 100

      Peak_Battery

      Min.: 0

      Max.: 100

      AC_Button

      Inactive or Active

      Auto_Button

      Inactive or Active

      Distri_Button

      Inactive or Active

      LUCH_Button

      Inactive or Active

      Mixing Button Front Left Minus

      Inactive or Active

      Mixing Button Front Left Plus

      Inactive or Active

      Blower button Front Minus

      Inactive or Active

      Blower button Front Plus

      Inactive or Active

      Recircu_Button

      Inactive or Active

      Visi_Button

      Inactive or Active

      Sunlight probe left side - raw data

      Min.: 0.00 V

      Max.: 5.00 V

      Sunlight probe Left side - converted data

      Min.: 0.0%

      Max.: 100.0%

      Front evaporator probe

      Min.: 0.00 V

      Max.: 5.00 V

      Front evaporator temperature probe value - converted data

      Min.: -40.0°C (-40°F)

      Max.: 120.0°C (248°F)

      BATTERY_VOLTAGE

      Min.: 0.0 V

      Max.: 24.0 V

      Air inlet motor position

      Min.: 0%

      Max.: 100%

      Distribution motor position front 1

      Min.: 0%

      Max.: 100%

      Front left mixing motor position

      Min.: 0%

      Max.: 100%

      Front blower setpoint

      Min.: 0%

      Max.: 100%

      Motor position during pre-positioning (Air inlet motor)

      Min.: 0%

      Max.: 100%

      Number of total travel steps (Air inlet motor)

      Min.: 0

      Max.: 50000

      Number of forcing and separation steps of the low thrust bearing (Air inlet motor)

      Min.: 0

      Max.: 255

      Number of forcing and separation steps of the high thrust bearing (Air inlet motor)

      Min.: 0

      Max.: 255

      Number of reversal steps (Air inlet motor)

      Min.: 0

      Max.: 255

      Number of overtravel steps (Air inlet motor)

      Min.: 0

      Max.: 255

      Motor position during pre-positioning (Mixing motor)

      Min.: 0%

      Max.: 100%

      Number of total travel steps (Mixing motor)

      Min.: 0

      Max.: 50000

      Number of forcing and separation steps of the low thrust bearing (Mixing motor)

      Min.: 0

      Max.: 255

      Number of forcing and separation steps of the high thrust bearing (Mixing motor)

      Min.: 0

      Max.: 255

      Number of reversal steps (Mixing motor)

      Min.: 0

      Max.: 255

      Number of overtravel steps (Mixing motor)

      Min.: 0

      Max.: 255

      Motor position during pre-positioning (Distribution motor)

      Min.: 0%

      Max.: 100%

      Number of total travel steps (Distribution motor)

      Min.: 0

      Max.: 50000

      Number of forcing and separation steps of the low thrust bearing (Distribution motor)

      Min.: 0

      Max.: 255

      Number of forcing and separation steps of the high thrust bearing (Distribution motor)

      Min.: 0

      Max.: 255

      Number of reversal steps (Distribution motor)

      Min.: 0

      Max.: 255

      Number of overtravel steps (Distribution motor)

      Min.: 0

      Max.: 255

      Distribution setpoint for manual resumption towards Ventilation outlet AV1

      Min.: 0%

      Max.: 100%

      Distribution setpoint for manual resumption towards Defrosting Ventilation outlet AV1

      Min.: 0%

      Max.: 100%

      Distribution setpoint for manual resumption towards Defrosting outlet AV1

      Min.: 0%

      Max.: 100%

      Distribution setpoint for manual resumption towards Feet outlet AV1

      Min.: 0%

      Max.: 100%

      Distribution setpoint for manual resumption towards Ventilation Feet outlet AV1

      Min.: 0%

      Max.: 100%

      Distribution setpoint for manual resumption towards Defrosting Ventilation Feet outlet AV1

      Min.: 0%

      Max.: 100%

      Distribution setpoint for manual resumption towards Defrosting Feet outlet AV1

      Min.: 0%

      Max.: 100%

      Motor max. speed threshold

      Min.: 0

      Max.: 100

      Motor take-off threshold

      Min.: 0

      Max.: 100

      Blower setpoint for manual resumption in speed 1

      Min.: 0%

      Max.: 100%

      Blower setpoint for manual resumption in speed 2

      Min.: 0%

      Max.: 100%

      Blower setpoint for manual resumption in speed 3

      Min.: 0%

      Max.: 100%

      Blower setpoint for manual resumption in speed 4

      Min.: 0%

      Max.: 100%

      Blower setpoint for manual resumption in speed 5

      Min.: 0%

      Max.: 100%

      Blower setpoint for manual resumption in speed 6

      Min.: 0%

      Max.: 100%

      Blower setpoint for manual resumption in speed 7

      Min.: 0%

      Max.: 100%

      Blower setpoint for manual resumption in speed 8

      Min.: 0%

      Max.: 100%

      Engine position after correction point 1 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 2 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 3 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 4 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 5 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 6 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 7 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 8 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 9 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 10 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 11 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 12 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 13 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 14 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 15 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 16 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 17 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 18 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 19 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 20 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 21 (Air inlet motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 1 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 2 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 3 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 4 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 5 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 6 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 7 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 8 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 9 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 10 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 11 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 12 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 13 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 14 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 15 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 16 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 17 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 18 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 19 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 20 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 21 (Mixing motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 1 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 2 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 3 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 4 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 5 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 6 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 7 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 8 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 9 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 10 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 11 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 12 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 13 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 14 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 15 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 16 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 17 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 18 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 19 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 20 (Distribution motor)

      Min.: 0

      Max.: 100

      Engine position after correction point 21 (Distribution motor)

      Min.: 0

      Max.: 100

      Min. sunlight voltage

      Min.: 0.0 V

      Max.: 5.0 V

      Max. sunlight voltage

      Min.: 0.0 V

      Max.: 5.0 V

      Pre-enable time

      0ms, 30ms, 60ms

      Post-enable time

      0ms, 30ms, 60ms

      Presence of a deceleration ramp

      Absent or Present

      Actuator rest time

      Min.: 0 ms

      Max.: 255 ms

      Low operating frequency of the air inlet actuator

      Rated operating frequency of the air inlet actuator, Operating frequency 2 of the air inlet actuator, Operating frequency 3 of the air inlet actuator, Operating frequency 4 of the air inlet actuator, Operating frequency 5 of the air inlet actuator, Operating frequency 6 of the air inlet actuator, Operating frequency 7 of the air inlet actuator, Operating frequency 8 of the air inlet actuator, Operating frequency 9 of the air inlet actuator, Operating frequency 10 of the air inlet actuator

      Rated operating frequency of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 2 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 3 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 4 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 5 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 6 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 7 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 8 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 9 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 10 of the air inlet actuator

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Low operating frequency of the micro-motors

      Rated operating frequency of the micro-motors, Operating frequency 2 of the micro-motors, Operating frequency 3 of the micro-motors, Operating frequency 4 of the micro-motors, Operating frequency 5 of the micro-motors, Operating frequency 6 of the micro-motors, Operating frequency 7 of the micro-motors, Operating frequency 8 of the micro-motors, Operating frequency 9 of the micro-motors, Operating frequency 10 of the micro-motors

      Rated operating frequency of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 2 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 3 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 4 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 5 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 6 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 7 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 8 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 9 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Operating frequency 10 of the micro-motors

      500Hz, 400Hz, 333Hz, 250Hz, 200Hz, 166Hz, 150Hz, 143Hz, 125Hz, 111Hz, 100Hz, 91Hz, 83Hz, 77Hz, 71Hz, 67Hz

      Low voltage threshold, air inlet hysteresis

      Min.: 8.0 V

      Max.: 16.0 V

      High voltage threshold, air inlet hysteresis

      Min.: 8.0 V

      Max.: 16.0 V

      Low voltage threshold, stepping motor hysteresis

      Min.: 8.0 V

      Max.: 16.0 V

      High voltage threshold, stepping motor hysteresis

      Min.: 8.0 V

      Max.: 16.0 V

      POWER_LATCH_DELAY

      Min.: 0 sec.

      Max.: 60 sec.

      HYST_SEUIL_BAS_PIL_MPAP

      Min.: 8.0 V

      Max.: 16.0 V

      HYST_SEUIL_HAUT_PIL_MPAP

      Min.: 8.0 V

      Max.: 16.0 V

      Distribution dynamic calibration strategy

      Calibration one time per session or Calibration at each travel limit

      Air inlet dynamic calibration strategy

      Calibration one time per session or Calibration at each travel limit

      Mixing dynamic calibration strategy

      Calibration one time per session or Calibration at each travel limit

      ACTIVATE_CLIM

      Inactive or Active

      IGNITION_OFF_TIME

      Min.: 0 min.

      Max.: 60 min.

      AMBIENT_TEMP

      Min.: -40°C (-40°F)

      Max.: 51°C (123.8°F)

      BACKLIGHTING_MODE

      Inactive (day) or Active (night)

      CRASH_INFORMATION

      Crash not detected or Crash detected

      DMD_AC

      Auto comfort, Auto visibility, Off

      DMD_BLOWER

      Auto, Speed 0, Speed 1, Speed 2, Speed 3, Speed 4, Speed 5, Speed 6, Speed 7, Speed 8

      DMD_DISTRIBUTION

      Auto comfort, Auto visibility, Feet, Ventilation, Defrost, Feet ventilation, Feet defrost, Feet defrost ventilation

      DMD_RECIRCULATION

      Auto comfort, Auto visibility, Closed forced, Auto comfort without AQS

      DMD_TEMP

      LO, X-7°C, X-6°C, X-5°C, X-4°C, X-3°C, X-1°C, Centered value, X+1°C, X+2°C, X+3°C, X+4°C, X+5°C, X+6°C, X+7°C, HI

      DMD_TYPING

      Soft, Normal, Fast

      DMD_VISIBILITY

      Inactive or Active

      ENGINE_SPEED

      Min.: 0.0 Rpm

      Max.: 10000.0 Rpm

      ENGINE_WATER_TEMP

      Min.: -47.25°C (-53.05°F)

      Max.: 143.25°C (289.85°F)

      EVAPO_TEMP

      Min.: -40.0°C (-40.0°F)

      Max.: 85.0°C (185.0°F)

      INIT_TEMP

      Min.: -40.0°C (-40°F)

      Max.: 85.0°C (185.0°F)

      SST_STATE

      Engine off, Engine on, To idling mode, Stop (Idling), Restart

      SUNLIGHT

      Min.: 0%

      Max.: 100%

      VEHICLE_SPEED

      Min.: 0 km/h

      Max.: 255 km/h

      ACTIVATE_CLIM_FLAG

      not requested or requested

      AMBIENT_TEMP_FLAG

      not requested or requested

      BACKLIGHTING_MODE_FLAG

      not requested or requested

      CRASH_INFORMATION_FLAG

      not requested or requested

      DMD_AC_FLAG

      not requested or requested

      DMD_BLOWER_FLAG

      not requested or requested

      DMD_DISTRIBUTION_FLAG

      not requested or requested

      DMD_RECIRCULATION_FLAG

      not requested or requested

      DMD_TEMP_FLAG

      not requested or requested

      DMD_TYPING_FLAG

      not requested or requested

      DMD_VISIBILITY_FLAG

      not requested or requested

      ENGINE_SPEED_FLAG

      not requested or requested

      ENGINE_WATER_TEMP_FLAG

      not requested or requested

      EVAPO_TEMP_FLAG

      not requested or requested

      INIT_TEMP_FLAG

      not requested or requested

      SST_STATE_FLAG

      not requested or requested

      SUNLIGHT_FLAG

      not requested or requested

      VEHICLE_SPEED_FLAG

      not requested or requested

      IGNITION_OFF_TIME_FLAG

      not requested or requested

      AC_TH

      Inactive or Active

      BLOWER_STATE

      Inactive or Active

      CMD_AIR_INLET

      Min.: 0%

      Max.: 100%

      MD_BLOWER

      Min.: 0%

      Max.: 100%

      CMD_DISTRIBUTION

      Min.: 0%

      Max.: 100%

      CMD_MIXING

      Min.: 0%

      Max.: 100%

      DCT_DMD

      Inactive or Active

      HMI_BLOWER_DEC

      Speed 1, Speed 2, Speed 3, Speed 4, Speed 5, Speed 6, Speed 7, Speed 8

      HMI_BLOWER_INC

      Speed 1, Speed 2, Speed 3, Speed 4, Speed 5, Speed 6, Speed 7, Speed 8

      SST_IMMEDIATE

      Inactive (No request) or Active (Request)

      PLAN_FONC High

      Min.: 0

      Max.: 16777215

      PLAN_FONC Low

      Min.: 0

      Max.: 65535

      CODE_FNR_2

      Min.: 12

      Max.: 12

      PROD_FONC High

      Min.: 0

      Max.: 16777215

      PROD_FONC Low

      Min.: 0

      Max.: 65535

      SOFT_VERSION

      Min.: 0

      Max.: 255

      SOFT_EDITION

      Min.: 0

      Max.: 255

      CALIB_VERSION

      Min.: 0

      Max.: 255

      CALIB_EDITION

      Min.: 0

      Max.: 255

      IND_MESS_DIAG

      Min.: 0

      Max.: 255

      NBR_PARAM_A_DEF

      Min.: 0

      Max.: 255

      REF_MESS_DIAG

      Min.: 0

      Max.: 4294967925

      CODE_FNR_1

      Min.: 12

      Max.: 12

      INITIAL_ORGANE_1

      Min.: 0

      Max.: 1

      INITIAL_ORGANE_2

      Min.: 0

      Max.: 1

      INITIAL_ORGANE_3

      Min.: 0

      Max.: 1

      INITIAL_ORGANE_4

      Min.: 0

      Max.: 1

      INITIAL_ORGANE_5

      Min.: 0

      Max.: 1

      ASCII Data

      Min.: 0

      Max.: 1

      IndCEM

      Min.: 0

      Max.: 255

  2. ACTIVE TEST

    Tip:

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Perform the Active Test according to the display on the GTS.

      Body Electrical > Air Conditioner > Active Test

      Tester Display

      Control Range

      Air Inlet Motor

      Min.: 0%

      Max.: 100%

      Mixing motor

      Min.: 0%

      Max.: 100%

      Distribution motor

      Min.: 0%

      Max.: 100%

      Blower motor

      Min.: 0%

      Max.: 100%

      Function indicators lighting

      Off or On

      LCD segments lighting

      Off or On

      AC_TH output

      Inactive or Active

      Memorizing Faults Prohibited

      Activate or Deactivate

      RAZ_CHARGE

      CPU or Battery

      Calibration of all the micro-motors

      Min.: 145

      Max.: 145