HORN SYSTEM INSPECTION


  1. INSPECT FUSE (HORN)

    A01E0O4E01

    1. Measure the resistance of the HORN fuse.

      Standard resistance
      Below 1 Ω

      If the result is not as specified, replace the fuse.

  2. INSPECT HORN ASSEMBLY

    A01DWL9E01

    1. Apply battery voltage and check operation of the horn.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) → Terminal 1

      Battery negative (-) → Horn bracket

      Horn sounds

      If the result is not as specified, replace the horn assembly.