GENERATOR REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  2. REMOVE INTAKE AIR CONNECTOR AND AIR CLEANER ASSEMBLY

    A01DYQWE01

    1. Disconnect the vacuum hose.

    2. Disconnect the No. 2 ventilation hose.

    3. Disconnect the MAF meter connector and wire harness clamps.

    4. Loosen the hose clamp and remove the 4 bolts, air cleaner and intake air connector assembly.

  3. REMOVE DRIVE BELT


    1. A01DZJYE01

      Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the drive belt. Then remove the drive belt.

      Note

      When removing the drive belt, do not use the idle pulley's bolt.

      Tech Tips

      After removing the drive belt, move the tensioner upward to the maximum amount.

  4. REMOVE GENERATOR ASSEMBLY


    1. A01DZY1E03

      Remove the nut, bolt and generator wire.

    2. Disconnect the generator connector.

    3. Remove the 2 bolts and generator.