| DTC Code | DTC Name |
|---|---|
| P2716 | Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
DESCRIPTION
Refer to DTC P0894 Click here.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2716 | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1 trip detection logic) |
|
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
Disconnect the E1 wire connector.
Measure the resistance of the wire connector.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
INSPECT SHIFT SOLENOID VALVE SLT Click here |
| OK |
|
CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)
Disconnect the E16 ECM connector.
Measure the resistance of the wire harness side connector.
| Standard resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS AND CONNECTOR |
| OK |
|
REPLACE ECM
INSPECT SHIFT SOLENOID VALVE SLT
Remove the shift solenoid valve SLT.
Measure the resistance of the solenoid valve.
| Standard resistance |
|---|
| 5.0 to 5.6 Ωat 20°C (68°F) |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
Check the operating noise of terminal 1 of the solenoid valve.
| OK |
|---|
| Solenoid makes operating noise. |
Tech Tips
Reference: Inspect using an oscilloscope.
Check the waveform of the ECM connector.
| OK | ||||||||
|---|---|---|---|---|---|---|---|---|
| Refer to illustration. | ||||||||
|
| NG |
|
REPLACE SHIFT SOLENOID VALVE SLT |
| OK |
|
REPAIR OR REPLACE TRANSMISSION WIRE