LIGHTING SYSTEM Interior Light Auto Cut Circuit
| DTC Code | DTC Name |
|---|---|
| Interior Light Auto Cut Circuit |
DESCRIPTION
The main body ECU (multiplex network body ECU) controls the DOME CUT relay.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
When replacing the main body ECU (multiplex network body ECU), make sure to replace it with a new one.
PROCEDURE
READ VALUE USING GTS (DOME CUT RELAY)
Using the GTS, read the Data List.
Body Electrical > Main Body > Active Test
Tester Display
Measurement Item
Control Range
Diagnostic Note
Relay for Interior Light Auto Cut Function
DOME CUT relay
ON or OFF
-
Body Electrical > Main Body > Active Test
Tester Display
Relay for Interior Light Auto Cut Function
OK
Battery saving control (interior light auto cut function) operates.
Result
Proceed to
OK
NG
INSPECT DOME CUT RELAY
-
Remove the DOME CUT relay from the No. 5 relay block*1 or No. 4 relay block*2.
*1: for LHD
*2: for RHD
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Battery voltage not applied between terminals 1 and 2
10 kΩ or higher
3 - 5
Battery voltage applied between terminals 1 and 2
Below 1 Ω
Result
Proceed to
OK
NG
NG REPLACE DOME CUT RELAY
-
CHECK HARNESS AND CONNECTOR (BATTERY - DOME CUT RELAY)
-
*A
for LHD
*B
for RHD
*a
Front view of wire harness connector
(to DOME CUT Relay)
Remove the DOME CUT relay from the No. 5 relay block*1 or No. 4 relay block*2.
*1: for LHD
*2: for RHD
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
DOME CUT relay terminal 2 - Body ground
Always
11 to 14 V
DOME CUT relay terminal 5 - Body ground
Always
11 to 14 V
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
-
CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - MAIN BODY ECU)
Remove the DOME CUT relay from the No. 5 relay block*1 or No. 4 relay block*2.
*1: for LHD
*2: for RHD
Disconnect the G78 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
DOME CUT relay terminal 1 - G78-15 (DOMR)
Always
Below 1 Ω
G78-15 (DOMR) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR