AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System), Diagnostic DTC:B14A2
| DTC Code | DTC Name |
|---|---|
| B14A2 | Driver Side Solar Sensor Short Circuit |
DESCRIPTION
The cooler (solar sensor) thermistor is installed on the upper side of the instrument panel. It detects sunlight to control air conditioning control in AUTO mode. The output voltage from the cooler (solar sensor) thermistor varies in accordance with the amount of sunlight. When the sunlight increases, the output voltage increases. As the sunlight decreases, the output voltage decreases. The air conditioning amplifier assembly detects changes in the output voltage from the cooler (solar sensor) thermistor.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
Memory |
|---|---|---|---|---|
B14A2 |
Driver Side Solar Sensor Short Circuit |
Short in driver side cooler (solar sensor) thermistor (for dual type) or cooler (solar sensor) thermistor (for single type) circuit |
|
Memorized (4 sec. or more)*1 |
*1: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
WIRING DIAGRAM
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
Body Electrical > Air Conditioner > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Solar Sensor (D Side)
Driver side cooler (solar sensor) thermistor*1 or cooler (solar sensor) thermistor*2
Min: 0
Max: 255
Driver side cooler (solar sensor) thermistor*1 or cooler (solar sensor) thermistor*2 value increase as brightness increases
-
*1: for Dual Type
*2: for Single Type
Body Electrical > Air Conditioner > Data List
Tester Display
Solar Sensor (D Side)
OK
The display is as specified in the normal condition column.
Result
Result
Proceed to
NG
A
OK (When troubleshooting according to Problem Symptoms Table)
B
OK (When troubleshooting according to the DTC)
C
B PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
Disconnect the F1*C or F4*D cooler (solar sensor) thermistor connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Table 1. for Dual type Tester Connection
Condition
Specified Condition
F1-1 (S5) - F1-3 (TSD)*A
Ignition switch off
Below 1 V
F1-1 (S5) - F1-3 (TSD)*A
Ignition switch ON
4.75 to 5.25 V
F1-1 (S5) - F1-2 (TSD)*B
Ignition switch off
Below 1 V
F1-1 (S5) - F1-2 (TSD)*B
Ignition switch ON
4.75 to 5.25 V
Standard Voltage
Table 2. for Single type Tester Connection
Condition
Specified Condition
F4-1 (SS+) - F4-2 (SS-)
Ignition switch off
Below 1 V
F4-1 (SS+) - F4-2 (SS-)
Ignition switch ON
4.75 to 5.25 V
*A: for LHD
*B: for RHD
*C: for Dual Type
*D: for Single Type
Result
Proceed to
OK
NG
NG CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER (SOLAR SENSOR) THERMISTOR)Click here
INSPECT COOLER (SOLAR SENSOR) THERMISTOR
Remove the cooler (solar sensor) thermistor.
Reconnect the F1*C or F4*D cooler (solar sensor) thermistor connector.
Turn the ignition switch to ON.
-
*A
for Single Type
*B
for Dual Type
*C
for LHD
*D
for RHD
*a
Component with harness connected
(Cooler (Solar Sensor) Thermistor)
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Table 3. for Dual type Tester Connection
Condition
Specified Condition
F1-1 (S5) - F1-3 (TSD)*A
Sensor is subjected to electric light
0.8 to 4.3 V
F1-1 (S5) - F1-3 (TSD)*A
Sensor is covered with a cloth
Below 0.8 V
F1-1 (S5) - F1-2 (TSD)*B
Sensor is subjected to electric light
0.8 to 4.3 V
F1-1 (S5) - F1-2 (TSD)*B
Sensor is covered with a cloth
Below 0.8 V
Standard Voltage
Table 4. for Single type Tester Connection
Condition
Specified Condition
F4-1 (SS+) - F4-2 (SS-)
Sensor is subjected to electric light
0.8 to 4.3 V
F4-1 (SS+) - F4-2 (SS-)
Sensor is covered with a cloth
Below 0.8 V
Note:The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the negative (-) lead to terminal 1 and the positive (+) lead to terminal 3*A, *C, 2*B, *C or 2*D of the cooler (solar sensor) thermistor.
Do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
Tip:Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler (solar sensor) thermistor.
As the inspection light is moved away from the sensor, the voltage decreases.
*A: for LHD
*B: for RHD
*C: for Dual Type
*D: for Single Type
Result
Proceed to
OK
NG
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER (SOLAR SENSOR) THERMISTOR)
Disconnect the E28 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 5. for Dual type Tester Connection
Condition
Specified Condition
E28-30 (S5-1) - F1-1 (S5)
Always
Below 1 Ω
E28-33 (TSD) - F1-3 (TSD)*A
Always
Below 1 Ω
E28-33 (TSD) - F1-2 (TSD)*B
Always
Below 1 Ω
E28-30 (S5-1) - Body ground
Always
10 kΩ or higher
E28-33 (TSD) - Body ground
Always
10 kΩ or higher
*A: for LHD
*B: for RHD
Standard Resistance
Table 6. for Single type Tester Connection
Condition
Specified Condition
E28-30 (S5-1) - F4-1 (SS+)
Always
Below 1 Ω
E28-33 (TSD) - F4-2 (SS-)
Always
Below 1 Ω
E28-30 (S5-1) - Body ground
Always
10 kΩ or higher
E28-33 (TSD) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
OK REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
for LHD:Click hereClick here
for RHD:Click hereClick here
NG REPAIR OR REPLACE HARNESS OR CONNECTOR