BLOWER UNIT (for Automatic Air Conditioning System) DISASSEMBLY


  1. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY


    1. A01DZ9KE01
      Text in Illustration
      *1 Lever

      Detach the claw and remove the lever.

    2. A01E1F2

      Remove the 3 screws and recirculation damper servo sub-assembly.

  2. REMOVE CLEAN AIR FILTER

    A01DZZ5

    1. Detach the claw and remove the air filter case.

    2. Remove the clean air filter.

  3. REMOVE BLOWER MOTOR CONTROL


    1. A01E13RE01

      w/o PTC Heater:

      Disconnect the 2 connectors and detach the 2 clamps and wire harness.

    2. w/ PTC Heater:

      Disconnect the 4 connectors and detach the 3 clamps and wire harness.

      Text in Illustration
      *A w/o PTC Heater
      *B w/ PTC Heater
    3. A01DYQC

      Remove the 3 screws and blower motor with fan sub-assembly.

  4. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

    A01DX7H

    1. Disconnect the connector.

    2. Remove the 2 screws and blower motor control.