DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE AIR CLEANER ASSEMBLY
w/ Mass Air Flow Meter:
Disconnect the mass air flow meter connector and detach the wire harness clamp.
Loosen the hose clamp, and then remove the air cleaner hose from the turbocharger.
Disconnect the ventilation hose and remove the 2 bolts and air cleaner.
w/o Mass Air Flow Meter:
Remove the clamp and disconnect the intake air temperature sensor connector.
Loosen the clamp of the turbocharger.
Slide the clamp and disconnect the ventilation hose.
Remove the 2 bolts and air cleaner.
REMOVE FAN AND GENERATOR V BELT
Using the pulley set bolt of the tensioner, rotate the tensioner pulley clockwise to loosen the belt's tension. Then remove the V belt.
REMOVE GENERATOR ASSEMBLY
Remove the nut and generator wire.
Disconnect the generator connector.
Remove the 2 bolts and generator.