RELAY ON-VEHICLE INSPECTION
PROCEDURE
INSPECT H-LP RELAY
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Voltage is not applied between terminals 1 and 2
10 kΩ or higher
3 - 5
Voltage is applied between terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the H-LP relay.
-
INSPECT DIMMER RELAY
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Voltage is not applied between terminals 1 and 2
10 kΩ or higher
3 - 5
Voltage is applied between terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the DIMMER relay.
-
INSPECT FR FOG RELAY (w/ Front Fog Light)
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Voltage is not applied between terminals 1 and 2
10 kΩ or higher
3 - 5
Voltage is applied between terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the FR FOG relay.
-
INSPECT DRL RELAY
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
Voltage is not applied between terminals 1 and 2
10 kΩ or higher
3 - 5
Voltage is applied between terminals 1 and 2
Below 1 Ω
If the result is not as specified, replace the DRL relay.
-