RELAY ON-VEHICLE INSPECTION

PROCEDURE

  1. INSPECT H-LP RELAY

    1. E209495

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Voltage is not applied between terminals 1 and 2

      10 kΩ or higher

      3 - 5

      Voltage is applied between terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the H-LP relay.

  2. INSPECT DIMMER RELAY

    1. E222294N09

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Voltage is not applied between terminals 1 and 2

      10 kΩ or higher

      3 - 5

      Voltage is applied between terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the DIMMER relay.

  3. INSPECT FR FOG RELAY (w/ Front Fog Light)

    1. E222294N09

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Voltage is not applied between terminals 1 and 2

      10 kΩ or higher

      3 - 5

      Voltage is applied between terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the FR FOG relay.

  4. INSPECT DRL RELAY

    1. E222294N09

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      3 - 5

      Voltage is not applied between terminals 1 and 2

      10 kΩ or higher

      3 - 5

      Voltage is applied between terminals 1 and 2

      Below 1 Ω

      If the result is not as specified, replace the DRL relay.