PROCEDURE
INSPECT CAM TIMING OIL CONTROL SOLENOID ASSEMBLY RH
| *a | Component without harness connected (cam timing oil control solenoid assembly RH) |
Apply battery voltage to the cam timing oil control solenoid assembly RH and check that the plunger operates.
| OK |
|---|
| The plunger extends outwards 4.3 mm (0.169 in.) or more. |
If the result is not as specified, replace the cam timing oil control solenoid assembly RH.