DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE AIR CLEANER ASSEMBLY
w/o EGR Cooler:
Disconnect the ventilation hose.
w/ Mass Air Flow Meter:
Disconnect the mass air flow meter sensor connector.
w/ Intake Air Temperature Sensor:
Disconnect the intake air temperature sensor connector.
Loosen the hose clamp.
Remove the 2 bolts and air cleaner assembly.
REMOVE FAN AND GENERATOR V BELT
Using the pulley set bolt of the tensioner, rotate the tensioner pulley clockwise to loosen the belt's tension. Then remove the V belt.
REMOVE GENERATOR ASSEMBLY
Remove the nut and generator wire.
Disconnect the generator connector.
Remove the 2 bolts and generator.