BACK DOOR CLOSER ECU INSTALLATION

CAUTION / NOTICE / HINT

Tip:

A bolt without a torque specification is shown in the standard bolt chart.

Click here

Note:

When replacing the multiplex network door ECU, the back door automatic open stop position (memory stopped position) is memorized, so be sure to make a note of the automatic open stop position.

PROCEDURE

  1. INSTALL MULTIPLEX NETWORK DOOR ECU

    1. B421529C02
      V100135

      Bolt

      V100136

      Connector

      Temporarily install the multiplex network door ECU by attaching the guide and clip of the multiplex network door ECU to the door panel.

    2. Install the multiplex network door ECU with the 2 bolts.

      8.4 N*m

      86 kgf*cm

      74 in.*lbf

    3. Connect the 2 connectors.

  2. INSTALL BACK DOOR TRIM BOARD ASSEMBLY

  3. INSTALL BACK DOOR SIDE GARNISH LH

  4. INSTALL BACK DOOR SIDE GARNISH RH

    Tip:

    Use the same procedure as for the LH side.

  5. INSTALL BACK DOOR CENTER GARNISH

  6. SET MULTIPLEX NETWORK DOOR ECU

    Tip:

    When replacing the multiplex network door ECU, be sure to set it to the back door memorized automatic open stop position (memory stopped position) before performing the replacement.

    Click hereClick here