СИСТЕМА АВТОМАТИЧЕСКОЙ ТРАНСМИССИИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ, Diagnostic DTC:P0973, P0974

DTC Code DTC Name
P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)
P0974 Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)

DESCRIPTION

Shifting from 1st to 4th (O/D) is performed in combination with "ON" and "OFF" operation of the shift solenoid valves S1, S2 and SL which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly Click here.

DTC No. DTC Detection Condition Trouble Area
P0973 ECM detects short in solenoid valve S1 circuit 2 times when solenoid valve S1 is operated (1-trip detection logic)
  • Short in shift solenoid valve S1 circuit

  • Shift solenoid valve S1

  • ECM

P0974 ECM detects open in solenoid valve S1 circuit 2 times when solenoid valve S1 is not operated (1-trip detection logic)
  • Open in shift solenoid valve S1 circuit

  • Shift solenoid valve S1

  • ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. When the shift solenoid valve S1 is on, if resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S1 circuit.

When the shift solenoid valve S1 is off, if resistance is 100 kΩ or more, the ECM determines there is an open in the shift solenoid valve S1 circuit Click here.

WIRING DIAGRAM

B007UBCE07

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (S1)


    1. B007U4IE14
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector from the transmission.

    2. Measure the resistance according to the value(s) in the table below.

      Resistance
      Tester Connection

      Specified Condition

      20°C (68°F)

      4 - Body ground 11 to 15 Ω

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. B007UCZE13
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Connect the transmission connector to the transmission.

    2. Disconnect the connector from the ECM.

    3. Measure the resistance according to the value(s) in the table below.

      Resistance
      Tester Connection

      Specified Condition

      20°C (68°F)

      D97-56 (S1) - Body ground 11 to 15 Ω

    NG
    OK
  3. INSPECT SHIFT SOLENOID S1


    1. B007PG2E03
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve S1)

      Remove the shift solenoid valve S1.

    2. Measure the resistance according to the value(s) in the table below.

      Resistance
      Tester Connection

      Specified Condition

      20°C (68°F)

      Solenoid Connector (S1) - Solenoid Body (S1) 11 to 15 Ω
    3. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK
      The solenoid makes an operating sound.

    NG
    OK