KNOCK SENSOR INSTALLATION

CAUTION / NOTICE / HINT

Tip:

Perform "Inspection After Repairs" after replacing the knock sensor (Click here).

PROCEDURE

  1. INSTALL KNOCK SENSOR

    1. U121327E02

      Install the knock sensor with the bolt.

      21 N*m

      214 kgf*cm

      15 ft.*lbf

      Note:

      Make sure that the knock sensor is in the correct position.

      Tip:

      Perform "Inspection After Repairs" after replacing the knock sensor (Click here).

    2. A173135

      Connect the knock sensor connector.

  2. INSTALL INTAKE MANIFOLD

    1. Install the intake manifold (Click hereClick here).