SELECT STROKE SENSOR INSPECTION

PROCEDURE

  1. INSPECT SELECT STROKE SENSOR

    1. C277417C03

      *a

      Main

      *b

      Select Stroke Sensor Arm

      *c

      55°

      *d

      *e

      -55°

      Measure the voltage between the terminals of the select stroke sensor connector (main).

      1. Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.

      2. Connect the batteries in series.

      3. Connect the positive battery terminal to sensor terminal 4 (VCL1), and the negative battery terminal to sensor terminal 5 (E2L1).

      4. Measure the voltage according to the value(s) in the table below.

        Table 1. Standard Voltage (combined dry cell battery voltage of 4.5 V)

        Tester Connection

        Condition

        (Sensor Angle)

        Specified Condition

        6 (VSL1) - 5 (E2L1)

        55°

        3.6 to 4.5 V

        1.8 to 2.7 V

        -55°

        0.27 to 0.63 V

        Table 2. Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)

        Tester Connection

        Sensor Angle

        Specified Condition

        6 (VSL1) - 5 (E2L1)

        55°

        4.0 to 5.0 V

        2.0 to 3.0 V

        -55°

        0.3 to 0.7 V

        If the voltage is not as specified, replace the select stroke sensor.

    2. C277417C04

      *a

      Sub

      *b

      Select Stroke Sensor Arm

      *c

      55°

      *d

      *e

      -55°

      Measure the voltage between the terminals of the select stroke sensor connector (sub).

      1. Connect the positive battery terminal to sensor terminal 1 (VCL2) , and the negative battery terminal to sensor terminal 2 (E2L2).

      2. Measure the voltage according to the value(s) in the table below.

        Table 3. Standard Voltage (combined dry cell battery voltage of 4.5 V)

        Tester Connection

        Condition

        (Sensor Angle)

        Specified Condition

        3 (VSL2) - 2 (E2L2)

        55°

        3.6 to 4.5 V

        1.8 to 2.7 V

        -55°

        0.27 to 0.63 V

        Table 4. Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)

        Tester Connection

        Sensor Angle

        Specified Condition

        3 (VSL2) - 2 (E2L2)

        55°

        4.0 to 5.0 V

        2.0 to 3.0 V

        -55°

        0.3 to 0.7 V

        Note:
        • Do not apply more than 6 V.

        • Do not use a sensor which has been dropped.

        If the voltage is not as specified, replace the select stroke sensor.