SELECT STROKE SENSOR INSPECTION
PROCEDURE
INSPECT SELECT STROKE SENSOR
-
*a
Main
*b
Select Stroke Sensor Arm
*c
55°
*d
0°
*e
-55°
Measure the voltage between the terminals of the select stroke sensor connector (main).
Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.
Connect the batteries in series.
Connect the positive battery terminal to sensor terminal 4 (VCL1), and the negative battery terminal to sensor terminal 5 (E2L1).
Measure the voltage according to the value(s) in the table below.
Table 1. Standard Voltage (combined dry cell battery voltage of 4.5 V) Tester Connection
Condition
(Sensor Angle)
Specified Condition
6 (VSL1) - 5 (E2L1)
55°
3.6 to 4.5 V
0°
1.8 to 2.7 V
-55°
0.27 to 0.63 V
Table 2. Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V) Tester Connection
Sensor Angle
Specified Condition
6 (VSL1) - 5 (E2L1)
55°
4.0 to 5.0 V
0°
2.0 to 3.0 V
-55°
0.3 to 0.7 V
If the voltage is not as specified, replace the select stroke sensor.
-
*a
Sub
*b
Select Stroke Sensor Arm
*c
55°
*d
0°
*e
-55°
Measure the voltage between the terminals of the select stroke sensor connector (sub).
Connect the positive battery terminal to sensor terminal 1 (VCL2) , and the negative battery terminal to sensor terminal 2 (E2L2).
Measure the voltage according to the value(s) in the table below.
Table 3. Standard Voltage (combined dry cell battery voltage of 4.5 V) Tester Connection
Condition
(Sensor Angle)
Specified Condition
3 (VSL2) - 2 (E2L2)
55°
3.6 to 4.5 V
0°
1.8 to 2.7 V
-55°
0.27 to 0.63 V
Table 4. Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V) Tester Connection
Sensor Angle
Specified Condition
3 (VSL2) - 2 (E2L2)
55°
4.0 to 5.0 V
0°
2.0 to 3.0 V
-55°
0.3 to 0.7 V
Note:Do not apply more than 6 V.
Do not use a sensor which has been dropped.
If the voltage is not as specified, replace the select stroke sensor.
-