CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P282B

DTC Code DTC Name
P282B Pressure Control Solenoid "K" Electrical (Shift Solenoid Valve SLS)

DESCRIPTION

According to current control by the ECM, the shift solenoid valve SLS controls secondary pulley pressure and belt clamping pressure in accordance with the input shaft torque.

C267073E08
Table 1. Text in Illustration

*1

Spool Valve

*2

Sleeve

*3

Solenoid Coil

-

-

*a

Hydraulic Pressure

*b

Current Flow to Solenoid

DTC Code

DTC Detection Condition

  1. Diagnosis Condition

  2. Malfunction Status

  3. Malfunction Time

  4. Other

Trouble Area

P282B

  1. The vehicle is being driven.

  2. An open or short circuit in the shift solenoid valve SLS circuit is detected.

  3. 1 second or more

  4. 1-trip detection logic

  • Wire harness or connector

  • Continuously variable transaxle assembly (Shift solenoid valve SLS)

  • ECM

MONITOR DESCRIPTION

This DTC indicates an open or short circuit in the shift solenoid valve SLS circuit. If there is an open or short circuit in the shift solenoid valve SLS circuit, the ECM detects the problem, illuminates the MIL and stores this DTC.

WIRING DIAGRAM

C262369E93

CAUTION / NOTICE / HINT

Note:
  • Perform initialization when parts related to the continuously variable transaxle are replaced (Click here).

  • Check that no DTCs are stored after performing initialization (Click here).

PROCEDURE

  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLS)

    1. C264597E35

      Disconnect the transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      5 (SLS+) - 12 (SLS-)

      20°C (68°F)

      5.0 to 5.6 Ω

      5 (SLS+) - Body ground and other terminals

      Always

      10 kΩ or higher

      12 (SLS-) - Body ground and other terminals

      Always

      10 kΩ or higher

      Table 2. Text in Illustration

      *a

      Component without harness connected

      (Transmission Wire)

    REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLYClick here

  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

    U123373E02
    1. Disconnect the ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      C111-45 (SLS+) - C111-44 (SLS-)

      20°C (68°F)

      5.0 to 5.6 Ω

      C111-45 (SLS+) - Body ground and other terminals

      Always

      10 kΩ or higher

      C111-44 (SLS-) - Body ground and other terminals

      Always

      10 kΩ or higher

      Table 3. Text in Illustration

      *a

      Front view of wire harness connector

      (to ECM)

    REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)

  3. REPLACE ECM

    1. Replace the ECM (Click here).

    PERFORM INITIALIZATION

  4. REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY

    1. Replace the continuously variable transaxle assembly (Click here).

    PERFORM INITIALIZATION