PURGE VALVE INSPECTION

PROCEDURE

  1. INSPECT PURGE VALVE (PURGE VSV)

    1. A194073E03

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      1 - 2

      20°C (68°F)

      23 to 26 Ω

      If the result is not as specified, replace the purge valve (purge VSV).

    2. A282778C01

      *a

      Port E

      *b

      Port F

      *c

      Air

      Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into port (E).

      OK

      Measurement Condition

      Specified Condition

      Battery voltage applied between terminals 1 and 2

      Air flows from port (F)

      Battery voltage not applied between terminals 1 and 2

      Air does not flow

      If the result is not as specified, replace the purge valve (purge VSV).