POWER WINDOW CONTROL SYSTEM All Power Windows do not Operate with Driver Side Door Key Cylinder or Wireless Transmitter

DESCRIPTION



CAUTION / NOTICE / HINT

Note


  • These functions are set through customize settings, as they are off by default.

  • The power window control system uses the LIN communication system and CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the power window control system after confirming that the communication systems are functioning properly.

    Click here

  • Check that power window system customize setting "Door Key P/W Up", "Door Key P/W Down", "P/W Up W/Transmit" and "P/W Down W/Transmit" are set to "ON" before performing the following procedure.

    Click here

  • If the main body ECU (multiplex network body ECU) is replaced, refer to Service Bulletin.*1


    • *1: w/ Entry and Start System

PROCEDURE


  1. CHECK BASIC FUNCTION (WIRELESS AND POWER DOOR LOCK CONTROL SYSTEM)


    1. Check that the wireless door lock/unlock function operates normally.



    2. Check that the key-linked lock/unlock function operates normally.

      Click here

      Result
      Result Proceed to
      Wireless door lock/unlock function and key-linked lock/unlock function operate normally A
      Wireless door lock/unlock function does not operate normally (w/ Entry and Start System) B
      Wireless door lock/unlock function does not operate normally (w/o Entry and Start System) C
      Key-linked lock/unlock function does not operate normally D

    B
    C
    D
    A
  2. CHECK MANUAL UP / DOWN FUNCTION


    1. Check that the manual up and down functions using the multiplex network master switch assembly and power window regulator switch assembly can operate all of the power windows.

      Click here

      OK
      Manual up and down functions are normal.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK REMOTE UP / DOWN FUNCTION


    1. Check that the remote up and down functions using the multiplex network master switch assembly can operate all of the power windows.

      Click here

      OK
      Remote up and down functions are normal.
      Result
      Result Proceed to
      OK (for LHD) A
      OK (for RHD) B
      NG C

    A
    B
    C