2ZR-FAE COOLING SERVICE DATA
Condition |
Specified Condition |
|
|---|---|---|
Standard valve opening temperature |
78 to 82°C (172 to 180°F) |
|
Standard valve lift |
for Type A |
10 mm (0.394 in.) or more at 93°C (199°F) |
for Type B |
10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F) |
|
Item |
Condition |
Specified Condition |
|---|---|---|
Indication Mark 43 Indication Mark 44 Indication Mark T5 Indication Mark T6 |
20°C (68°F) |
7.4 to 10.9 A |
Indication Mark T7 Indication Mark T8 Indication Mark T0 |
20°C (68°F) |
11.2 to 15.2 A |
Item |
Condition |
Specified Condition |
|---|---|---|
Cooling fan motor |
Less than 95°C (203°F) |
2 to 15.2 A |
Item |
Condition |
Specified Condition |
|---|---|---|
Radiator reservoir cap |
Standard value (for brand-new cap) |
93 to 123 kPa (1.0 to 1.3 kgf/cm2, 13.5 to 18 psi) |
Minimum standard value (after using cap) |
79 kPa (0.8 kgf/cm2, 11.4 psi) |