GENERATOR(for 80A Type) REMOVAL
PROCEDURE
PRECAUTION
Note:After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
REMOVE FRONT BUMPER ASSEMBLY
REMOVE V-RIBBED BELT
REMOVE GENERATOR ASSEMBLY
-
*1
Terminal Cap
*2
Wire Harness
*a
Generator Assembly Connector
Remove the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Disconnect the generator assembly connector and disengage the 2 wire harness clamps.
-
Remove the 2 bolts and generator assembly.
-
Remove the 2 bolts and 2 wire harness clamp brackets.
-