GENERATOR(for 80A Type) REMOVAL

PROCEDURE

  1. PRECAUTION

    Note:

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

    Click hereClick here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick hereClick here

  3. REMOVE FRONT BUMPER ASSEMBLY

  4. REMOVE V-RIBBED BELT

  5. REMOVE GENERATOR ASSEMBLY

    1. A322654C01

      *1

      Terminal Cap

      *2

      Wire Harness

      *a

      Generator Assembly Connector

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the generator assembly connector and disengage the 2 wire harness clamps.

    4. A322655

      Remove the 2 bolts and generator assembly.

    5. A322656

      Remove the 2 bolts and 2 wire harness clamp brackets.