SHIFT AND SELECT ACTUATOR INSPECTION
PROCEDURE
INSPECT SHIFT AND SELECT ACTUATOR ASSEMBLY
Select motor side:
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Resistance
1 - 2
0.1 to 100 Ω
If the resistance is not as specified, replace the shift and select actuator assembly.
-
Shift motor side:
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Resistance
1 - 2
0.1 to 100 Ω
If the resistance is not as specified, replace the shift and select actuator assembly.
-