STOP AND START SYSTEM Stop and Start System does not Operate (Battery Condition)
| DTC Code | DTC Name |
|---|---|
| Stop and Start System does not Operate (Battery Condition) |
DESCRIPTION
When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.
Oper Permission (Battery) |
Oper Permission (Start Min Volt 1) |
Oper Permission (Start Min Volt 2) |
Oper Permission (Start Min Volt 3) |
Oper Permission (Start Min Volt 4) |
Oper Permission (Battery Current) |
Oper Permission (Integrated Current) |
Oper Prohibition (Jump Start) |
PROCEDURE
CONFIRM MODEL
Choose the model to be inspected.
Result
Result
Proceed to
for Multi-information Display (Color Type)
A
except Multi-information Display (Color Type)
B
B CHECK DTC OUTPUTClick here
CHECK MULTI-INFORMATION DISPLAY
Check whether the multi-information display displayed that the specified battery is not equipped.
Tip:The multi-information display is displayed when the voltage decreases below the minimum voltage necessary for starting the non-specified battery when stop and start control is operated.
Result
Result
Proceed to
No display
A
Displayed in past
B
A CHECK DTC OUTPUTClick here
B READ VALUE USING GTS (BATTERY TYPE)Click here
CHECK DTC OUTPUT
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Trouble Codes.
Read the DTCs.
Powertrain > Stop and Start > Trouble Codes
Result
Result
Proceed to
DTC is not output
A
DTC is output
B
READ VALUE USING GTS
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed
-
Oper Permission (Start Min Volt 1)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Battery Current)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery discharge current is -125 A or less
Engine stop and start ECU calculated value
Oper Permission (Integrated Current)
Permission of stop and start control based on the integrated current value conditions
NG/OK
OK: Integrated current value more than specified
The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.
Oper Prohibition (Jump Start)
Prohibition of stop and start control based on the jump start conditions
Permit/Prohibit
Prohibit: Engine started with the engine hood open and the ignition switch turned to START
When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
Oper Prohibition (Manual Start)
Prohibition of stop and start control based on the manual start conditions
Permit/Prohibit
Prohibit: During manual start
When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
Conditions for Manual Start:
Clutch start switch OFF or vehicle speed signal input
Neutral position switch OFF
Starter signal OFF
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
Oper Permission (Battery Current)
Oper Permission (Integrated Current)
Oper Prohibition (Jump Start)
Oper Prohibition (Manual Start)
Result
Proceed to
NEXT
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether stop and start control was prohibited based on the battery conditions or other conditions.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Type
Range
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Result
Proceed to
NG is displayed
A
OK is displayed
B
READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)
Tip:Check whether stop and start control was prohibited based on the battery charge control mode.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Status of Battery Charge Control
Battery charge control status
Charge Control Coordination Mode/Stop and Start Standalone Mode/Refresh Charge Mode/Stop and Start Restriction Mode/Temperature High/Low Mode/Abnormal Mode/Battery Condition Judgment Mode/Low Temperature Mode
-
-
Powertrain > Stop and Start > Data List
Tester Display
Status of Battery Charge Control
Result
Result
Proceed to
"Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed
A
"Refresh Charge Mode" is displayed
B
"Battery Condition Judgment Mode" is displayed
C
"Abnormal Mode" is displayed
D
Tip:If "Refresh Charge Mode" is displayed, leave the vehicle idling for 30 to 60 minutes.
B END (STOP AND START CONTROL PROHIBITED IN REFRESH CHARGE MODE)
C END (STOP AND START CONTROL PROHIBITED IN BATTERY CONDITION JUDGMENT MODE)
D GO TO CHARGING SYSTEM
for 1ND-TV:Click hereClick hereClick here
for 1WW:Click hereClick here
for 8NR-FTS:Click hereClick here
READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))
Tip:Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Start Min Volt 1)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 2)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when cranking is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 3)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is 0°C (32°F) or lower and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Oper Permission (Start Min Volt 4)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery temperature is higher than 0°C (32°F) and minimum voltage when starter begins operation is equal to or above threshold
If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Start Min Volt 1)
Oper Permission (Start Min Volt 2)
Oper Permission (Start Min Volt 3)
Oper Permission (Start Min Volt 4)
Result
Result
Proceed to
OK is displayed for 2 or more items
A
OK is displayed for 1 item or none
B
The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Temp (Start)
Battery temperature at engine start
Min.: -40°C (-40°F), Max.: 100°C (212°F)
Same as temperature around battery at engine start (after engine start)
-
Min Voltage(Cranking)
Minimum battery voltage while engine cranking (incurrent trip)
Min.: 0 V ,Max.: 327.67 V
6 to 11 V
Lowest battery voltage measured in a 5 second period after the starter starts operating.
Min Volt(After Cranking)
Minimum battery voltage just after engine cranking
Min.: 0 V ,Max.: 40 V
6 to 11 V
Minimum battery voltage while starter driving
Battery Type
Set battery type
Specified/Other
Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Temp (Start)
Min Voltage(Cranking)
Min Volt(After Cranking)
Battery Type
Permission Criteria (except 8NR-FTS)
Tester Display
Starting Battery Voltage
Battery Temperature*1
Oper Permission (Start Min Volt 1)*2
6.6 V or higher*4
6.5 V or higher*5
0°C (32°F) or lower
Oper Permission (Start Min Volt 2)*2
6.6 V or higher*4
6.5 V or higher*5
Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3)*3
6.6 V or higher*4
6.5 V or higher*5
0°C (32°F) or lower
Oper Permission (Start Min Volt 4)*3
6.6 V or higher*4
6.5 V or higher*5
Higher than 0°C (32°F)
*1: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.
*2: Min Voltage (Cranking)
*3: Min Volt (After Cranking)
*4: for 1WW
*5: for 1ND-TV
Permission Criteria (Specified Battery) (for 8NR-FTS)
Tester Display
Starting Battery Voltage
Battery Temperature*1
Oper Permission (Start Min Volt 1)*2
8.14 V or higher*4
7.2 V or higher*5
0°C (32°F) or lower
Oper Permission (Start Min Volt 2)*2
8.14 V or higher*4
7.2 V or higher*5
Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3)*3
7.6 V or higher*4
7.2 V or higher*5
0°C (32°F) or lower
Oper Permission (Start Min Volt 4)*3
7.6 V or higher*4
7.2 V or higher*5
Higher than 0°C (32°F)
*1: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.
*2: Min Voltage (Cranking)
*3: Min Volt (After Cranking)
*4: for CVT
*5: for Manual Transaxle
Permission Criteria (Non-specified Battery) (for 8NR-FTS)
Tester Display
Starting Battery Voltage
Battery Temperature*1
Oper Permission (Start Min Volt 1)*2
8.92 V or higher
0°C (32°F) or lower
Oper Permission (Start Min Volt 2)*2
8.92 V or higher
Higher than 0°C (32°F)
Oper Permission (Start Min Volt 3)*3
8.92 V or higher
0°C (32°F) or lower
Oper Permission (Start Min Volt 4)*3
8.92 V or higher
Higher than 0°C (32°F)
*1: Read the Data List items "Battery Temp (Start)" when checking the battery temperature.
*2: Min Voltage (Cranking)
*3: Min Volt (After Cranking)
B READ VALUE USING GTS (BATTERY TYPE)Click here
READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))
Tip:Check whether the stop and start control was prohibited based on the battery discharge current battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery Current)
Permission of stop and start control based on the battery conditions
NG/OK
OK: Battery discharge current is -125 A or less
Engine stop and start ECU calculated value
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery Current)
Result
Result
Proceed to
OK is displayed
A
NG is displayed
B
The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Current
Battery current
Min.: 0 A, Max.: 124.99 A
-
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Current
Permission Criteria
Tester Display
Battery Current
Oper Permission (Battery Current)
-125 A or less
B END (REDUCE ELECTRICAL LOAD)
READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))
Tip:Check whether the stop and start control was prohibited based on the integrated current value battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Integrated Current)
Permission of stop and start control based on the integrated current value conditions
NG/OK
OK: Integrated current value more than specified
The condition is judged based on the integrated current value.
The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Integrated Current)
Result
Result
Proceed to
OK is displayed
A
NG is displayed
B
B READ VALUE USING GTS (INTEGRATED CURRENT)Click here
READ VALUE USING GTS (STATE OF BBC AND BBC CHECK RESULT)
Tip:Check the operation of the backup boost converter.
Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC and BBC Check Result.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
State of BBC
Backup boost converter status
Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset status
Normal: Backup boost converter operating normally
Cycle Err:
-
Abnormal output voltage cycle is detected
Overvol:
-
When the ignition switch is ON:
-
Overvoltage is detected at the control IC power source within the backup boost converter
Overheating is detected at the control IC power source within the backup boost converter
-
When boosting:
-
Error is detected in the feedback circuit in the backup boost converter
Too high or low output voltage
Overload:
-
Overcurrent is detected.
Low Vol:
-
A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.
Duty Err:
-
Abnormal duty ratio is detected
BBC Check Result
Backup boost converter check result
Normal / Abnormal
-
-
Powertrain > Stop and Start > Data List
Tester Display
State of BBC
BBC Check Result
Result
Result
Proceed to
Normal is displayed
A
Normal is not displayed
B
B GO TO BACKUP BOOST CONVERTER CIRCUIT
READ VALUE USING GTS (OPER PROHIBITION (JUMP START))
Tip:Check whether stop and start control was prohibited based on the jump start battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Prohibition (Jump Start)
Prohibition of stop and start control based on the jump start conditions
Permit / Prohibit
Prohibit: Engine started with the engine hood open and the ignition switch turned to START
When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
Powertrain > Stop and Start > Data List
Tester Display
Oper Prohibition (Jump Start)
Result
Result
Proceed to
Permit is displayed
A
Prohibit is displayed
B
The Data List item "Oper Permission (Jump Start)" is judged Permit or Prohibit according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Hood Courtesy Switch
Hood courtesy switch signal
ON / OFF
ON: Engine hood closed
OFF: Engine hood open
-
Oper Permission (Engine Hood Closed)
Permission of stop and start control based on the engine hood open/close conditions
NG / OK
OK: Engine hood closed
-
Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
Oper Permission (Engine Hood Closed)
Permission Criteria
Tester Display
Conditions
Oper Prohibition (Jump Start)
ON (Engine hood closed) is displayed for Hood Courtesy Switch
OK (Engine Hood Closed) is displayed for Oper Permission (Engine Hood Closed)
B READ VALUE USING GTS (HOOD COURTESY SWITCH)Click here
READ VALUE USING GTS (OPER PROHIBITION (MANUAL START))
Tip:Check whether the stop and start control was prohibited based on the manual start battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Manual Start).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Prohibition (Manual Start)
Prohibition of stop and start control based on the manual start conditions
Permit / Prohibit
Prohibit: During manual start
When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
Conditions for Manual Start:
Clutch start switch OFF or vehicle speed signal input
Neutral position switch OFF
Starter signal OFF
Powertrain > Stop and Start > Data List
Tester Display
Oper Prohibition (Manual Start)
Result
Result
Proceed to
Permit is displayed
A
Prohibit is displayed
B
Tip:If Prohibit is displayed, start the engine using a key.
B END (STOP AND START CONTROL PROHIBITED DUE TO MANUAL START OPERATION)
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether the stop and start control was prohibited based on the battery temperature battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery conditions
NG / OK
OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Result
Proceed to
NG is displayed
A
OK is displayed
B
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Fluid Temperature
Battery temperature
Min.: -40°C (-40°F), Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up
-
Ambient Temp Sensor
Ambient temperature
Min.: -80°C (-112°F), Max.: 79.9°C (175.8°F)
Close to ambient temperature
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temp Sensor
Permission Criteria
Tester Display
Battery Temperature*
Oper Permission (Battery)
Current battery temperature is between -10°C (14°F) and 70°C (158°F)
Tip:*: Read the Data List items "Battery Fluid Temperature" and "Ambient Temp Sensor" when checking the battery temperature.
B END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)
READ VALUE USING GTS (BATTERY TEMPERATURE)
Tip:Check the battery temperature.
Enter the following menus: Powertrain / Stop and Start / Data List.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Fluid Temperature
Battery temperature
Min.: -40°C (-40°F), Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up
-
Ambient Temp Sensor
Ambient temperature
Min.: -80°C (-112°F), Max.: 79.9°C (175.8°F)
Close to ambient temperature
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Ambient Temp Sensor
Result
Result
Proceed to
Both "Battery Fluid Temperature" and "Ambient Temp Sensor" are as specified
A
"Battery Fluid Temperature" or "Ambient Temp Sensor" is not as specified
B
Tip:If the battery temperature is not as specified, leave the battery under room temperature conditions until its temperature becomes as specified.
B END (STOP AND START CONTROL PROHIBITED DUE TO ABNORMAL BATTERY TEMPERATURE)
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether stop and start control was prohibited based on the alternator status battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery conditions
NG / OK
OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Result
Proceed to
NG is displayed
A
OK is displayed
B
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Alternator Status
Alternator power generation status
Normal / Abnormal
Normal: Alternator operation normal
-
Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
Permission Criteria
Tester Display
Conditions
Oper Permission (Battery)
Normal is displayed for Alternator Status (Alternator is generating power)
Charge indicator lamp is off when the engine is running (Alternator is generating power)
B END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)
READ VALUE USING GTS (ALTERNATOR STATUS)
Tip:Check the power generation status of the alternator.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Alternator Status
Alternator power generation status
Normal / Abnormal
Normal: Alternator operation normal
-
Powertrain > Stop and Start > Data List
Tester Display
Alternator Status
Result
Result
Proceed to
Normal is displayed
A
Abnormal is displayed
B
B GO TO CHARGING SYSTEM
for 1ND-TV:Click hereClick hereClick here
for 1WW:Click hereClick here
for 8NR-FTS:Click hereClick here
READ VALUE USING GTS (OPER PERMISSION (BATTERY))
Tip:Check whether stop and start control was prohibited based on the idling stop rate battery condition.
Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Oper Permission (Battery)
Permission of stop and start control based on the battery conditions
NG / OK
OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed
-
Powertrain > Stop and Start > Data List
Tester Display
Oper Permission (Battery)
Result
Result
Proceed to
NG is displayed
A
OK is displayed
B
The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Idling Stop Rate
Rate of the idling stop time to the entire ignition switch ON time
Min.: 0%, Max.: 100%
-
-
Total Idling Stop Rate
Rate of total idling stop time
Min.: 0%, Max.: 100%
-
-
Powertrain > Stop and Start > Data List
Tester Display
Idling Stop Rate
Total Idling Stop Rate
Permission Criteria
Tester Display
Condition
Oper Permission (Battery)
Idling Stop Rate is 50% or less and Total Idling Stop Rate is 40% or less
Tip:If Idling Stop Rate exceeds 50%, stop and start control will not be permitted until Idling Stop Rate drops to 47% or less.
B END (CHECK OTHER STOP AND START CONTROL PERMISSION/PROHIBITION CONDITIONS)
READ VALUE USING GTS (IDLING STOP RATE)
Tip:Check the idling stop rate.
Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Idling Stop Rate
Rate of the idling stop time to the entire ignition switch ON time
Min.: 0%, Max.: 100%
-
-
Total Idling Stop Rate
Rate of total idling stop time
Min.: 0%, Max.: 100%
-
-
Powertrain > Stop and Start > Data List
Tester Display
Idling Stop Rate
Total Idling Stop Rate
Result
Result
Proceed to
Idling Stop Rate is higher than 50% or Total Idling Stop Rate is 40% or higher
A
Idling Stop Rate is 50% or lower and Total Idling Stop Rate is 40% or lower
B
Tip:If Idling Stop Rate is higher than 50% or Total Idling Stop Rate is higher than 40%, turn the ignition switch off and leave the vehicle off for a while. After that, restart the engine. If the Data List item "Oper Permission (Battery)" still shows not permitted, the battery may be degraded or temporarily discharging. In that case, charge or replace the battery after checking the battery state.
A END (STOP AND START PROHIBITED DUE TO IDLING STOP RATE 50% OR MORE OR TOTAL IDLING STOP RATE 40% OR MORE)
B CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE CURRENT SUM VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)
READ VALUE USING GTS (HOOD COURTESY SWITCH)
Tip:Check the engine hood courtesy switch (hood lock assembly).
Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Hood Courtesy Switch
Hood courtesy switch signal
ON / OFF
ON: Engine hood closed
OFF: Engine hood opened
-
Powertrain > Stop and Start > Data List
Tester Display
Hood Courtesy Switch
Result
Result
Proceed to
OK
A
NG
B
Tip:If the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.
A END (STOP AND START CONTROL PROHIBITED DUE TO ENGINE START WITH ENGINE HOOD OPEN)
READ VALUE USING GTS (INTEGRATED CURRENT)
Tip:Judge the battery condition based on the integrated current value.
Start the engine and allow it to idle.
Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.
According to the display on the GTS, read the Data List.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Integrated Current
Battery integrated current
Min.: -268434.45 A-sec, Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge / discharge conditions)
-
Powertrain > Stop and Start > Data List
Tester Display
Integrated Current
Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Fluid Temperature
Battery fluid temperature
Min.: -40°C (-40°F), Max.: 100°C (212°F)
Changes according to actual temperature: Driving after engine warmed up
-
Battery Current
Battery current
Min.: 0 A, Max.: 124.99 A
-
-
Integrated Current
Battery integrated current
Min.: -268434.45 A-sec, Max.: 268435.45 A-sec
Differs according to the vehicle condition (charge / discharge conditions)
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Fluid Temperature
Battery Current
Integrated Current
Standard Integrated Current Value (for 1WW)
Status of Battery Charge Control
Battery Temperature
Integrated Current
Proceed to
Charge Control Coordination Mode or Low Temperature Mode
-
Below -5299 A-sec
A
Stop and Start Standalone Mode, Stop and Start Restriction Mode or Temperature High/Low Mode
-15°C (5°F) or higher and below 75°C (167°F)
Below 0 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode
Below -15°C (5°F) or 75°C (167°F) or higher
-
B
Standard Integrated Current Value (for 1ND-TV)
Status of Battery Charge Control
Battery Temperature
Integrated Current
Proceed to
Charge Control Coordination Mode or Low Temperature Mode
-
Below -3974 A-sec
A
Stop and Start Standalone Mode, Stop and Start Restriction Mode or Temperature High/Low Mode
-15°C (5°F) or higher and below 75°C (167°F)
Below 0 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode
Below -15°C (5°F) or 75°C (167°F) or higher
-
B
Standard Integrated Current Value (for 8NR-FTS)
Status of Battery Charge Control
Battery Temperature
Integrated Current
Proceed to
Charge Control Coordination Mode, Stop and Start Standalone Mode or Low Temperature Mode
-
Below -3974 A-sec
A
Stop and Start Restriction Mode or Temperature High/Low Mode
-15°C (5°F) or higher and below 75°C (167°F)
Below 0 A-sec
Stop and Start Restriction Mode or Temperature High/Low Mode
Below -15°C (5°F) or 75°C (167°F) or higher
-
B
Cause and Action to be Taken
Result
Cause
Action to be Taken
A
Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery
Check the battery condition and recharge or replace the battery
B
Integrated current value is limited for stop and start control due to battery temperature (too high/low)
Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery.
Initialize* the battery integrated current using the GTS after charging the battery, and drive the vehicle until the stop and start control operates (approximately 5 to 40 minutes).
*: Use the GTS to perform Integrated Current Value Initialization.
When the battery sensor current value is normal, recharge or replace the battery
Result
Proceed to
NEXT
NEXT END (RECHARGE OR REPLACE BATTERY)
READ VALUE USING GTS (BATTERY TYPE)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
Check the "Battery Type" Data List Item.
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Type
Set battery type
Specified / Other
Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
Check whether the battery is specified or not specified.
Result
Data List Battery Type Display
Equipped Battery
Proceed to
Other
Specified battery
A
Other
Non-specified battery
B
Specified
-
C
B EXPLAIN TO CUSTOMER THAT STOP AND START SYSTEM IS LIMITED TO PREVENT BATTERY MALFUNCTION WHEN A NON-SPECIFIED BATTERY IS USED
C CHARGE OR REPLACE BATTERY AFTER CHECKING BATTERY STATE AND THEN INITIALIZE CURRENT SUM VALUE AND DRIVE VEHICLE UNTIL STOP AND START CONTROL OPERATES (APPROXIMATELY 5 TO 40 MINUTES)
SWITCH BATTERY TYPE
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Utility / Switch Battery Type.
Powertrain > Engine > Utility
Tester Display
Switch Battery Type
Perform Switch Battery Type under Utility and set the Specified battery.
Enter the following menus: Powertrain / Stop and Start / Data List / Battery Type.
Check that the "Battery Type" Data List item is set to "Specified".
Powertrain > Stop and Start > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Type
Set battery type
Specified / Other
Specified: Specified battery
Other: Non-specified battery
-
Powertrain > Stop and Start > Data List
Tester Display
Battery Type
Result
Proceed to
NEXT
NEXT END