IGNITION SWITCH INSPECTION
PROCEDURE
INSPECT IGNITION SWITCH ASSEMBLY
-
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Switch Condition
Specified Condition
-
LOCK
10 kΩ or higher
2 (AM1) - 3 (ACC)
ACC
Below 1 Ω
2 (AM1) - 3 (ACC)
2 (AM1) - 4 (IG1)
6 (IG2) - 7 (AM2)
ON
Below 1 Ω
1 (ST1) - 2 (AM1)
1 (ST1) - 4 (IG1)
6 (IG2) - 7 (AM2)
6 (IG2) - 8 (ST2)
START
Below 1 Ω
Table 1. Text in Illustration *1
Component without harness connected
(Ignition Switch)
If the result is not as specified, replace the ignition switch assembly.
-