ULTRASONIC SENSOR INSPECTION
PROCEDURE
INSPECT NO. 3 ULTRASONIC SENSOR
-
*a
Component without harness connected
(No. 3 Ultrasonic Sensor)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (BI) - 5 (EI)
Always
10 kΩ or higher
1 (BI) - 2 (BO)
Always
10 kΩ or higher
3 (SI) - 4 (SO)
Always
Below 1 Ω
5 (EI) - 6 (EO)
Always
Below 1 Ω
If the result is not as specified, replace the No. 3 ultrasonic sensor.
-