HYBRID BATTERY SYSTEM, Diagnostic DTC:P0ABF-123, P0AC1-123, P0AC2-123, P0B10-123, P0B11-123

DTC Code DTC Name
P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
P0AC1-123 Hybrid Battery Pack Current Sensor Circuit Low
P0AC2-123 Hybrid Battery Pack Current Sensor Circuit High
P0B10-123 Hybrid Battery Pack Current Sensor "B" Circuit Low
P0B11-123 Hybrid Battery Pack Current Sensor "B" Circuit High

DESCRIPTION


DTC No. INF Code DTC Detection Condition Trouble Area

P0ABF

P0AC1

P0AC2

P0B10

P0B11

123 When the battery current sensor is abnormal (1 trip detection)
  • Hybrid battery junction block assembly

  • Battery smart unit

  • Wire harness or connector

  • HV battery

WIRING DIAGRAM

A005ETBE01
*a Battery Current Sensor (Hybrid Battery Junction Block Assembly)
*b Battery Smart Unit

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

Tech Tips

If a short to +B occurs in the battery temperature sensor, battery current sensor or intake air temperature sensor, the following DTCs may be output simultaneously.

DTC No. Relevant Diagnosis
P0ABF-123 Hybrid Battery Pack Current Sensor Circuit
P0A9E-123 Hybrid Battery Temperature Sensor "A" Circuit High
P0AC8-123 Hybrid Battery Temperature Sensor "B" Circuit High
P0ACD-123 Hybrid Battery Temperature Sensor "C" Circuit High
P0AEB-123 Hybrid Battery Temperature Sensor "D" Circuit High
P0BC5-123 Hybrid Battery Temperature Sensor "E" Circuit High
P0C36-123 Hybrid Battery Temperature Sensor "F" Circuit High
P0AAF-123 Hybrid Battery Pack Air Temperature Sensor "A" Circuit High
P0AB4-123 Hybrid Battery Pack Air Temperature Sensor "B" Circuit High

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Read output DTCs Click here.

      Result
      Result Proceed to
      P0AFC-123 is not output. A
      P0AFC-123 is also output. B
    5. Turn the power switch off.


    B
    A
  2. CHECK HARNESS AND CONNECTOR (B AND IGCT VOLTAGE)

    Note

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 hybrid battery shield sub-assembly Click here.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

      Note

      Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. A005D41E02
      Text in Illustration
      *a

      Component with harness connected

      (Battery Smart Unit)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      L144-1 (B) - L144-4 (GND) Power switch off 8.6 V or more
      L144-5 (IGCT) - L144-4 (GND) Power switch on (IG) 8.6 V or more

      Tech Tips

      As there might be an intermittent malfunction in the battery voltage sensor power source circuit, inspect the following even if the measured voltage is as specified:


      • Installation condition of fuse(s) (before removing fuse(s)) (IGCT circuit)

      • Fuse condition (before and after removing fuse(s)) (IGCT circuit)

      • Connection condition of connectors (IGCT circuit)

      • Wire harness condition (IGCT circuit)

      • Wire harness condition (GND circuit)

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Install the No. 1 hybrid battery shield sub-assembly.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (BATTERY SMART UNIT - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

    Note

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 2 hybrid battery shield sub-assembly Click here.

    3. Disconnect the z25 hybrid battery junction block assembly connector.

    4. A005CXYE02
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Battery Smart Unit)

      *b

      Front view of wire harness connector

      (to Hybrid Battery Junction Block Assembly)

      Disconnect the z24 battery smart unit connector.

    5. Measure the resistance according to the value(s) in the tables below.

      A0059XWE01
      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      z24-11 (IB1) - z25- 2 (IB1) Power switch off Below 1 Ω
      z24-12 (GIB) - z25- 3 (GIB) Power switch off Below 1 Ω
      z24-23 (IB0) - z25- 4 (IB0) Power switch off Below 1 Ω
      z24-24 (VIB) - z25- 1 (VIB) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      z24-11 (IB1) or z25- 2 (IB1) - Body ground and other terminals Power switch off 10 kΩ or higher
      z24-12 (GIB) or z25- 3 (GIB) - Body ground and other terminals Power switch off 10 kΩ or higher
      z24-23 (IB0) or z25- 4 (IB0) - Body ground and other terminals Power switch off 10 kΩ or higher
      z24-24 (VIB) or z25- 1 (VIB) - Body ground and other terminals Power switch off 10 kΩ or higher
    6. Reconnect the z25 hybrid battery junction block assembly connector.

    7. Reconnect the z24 battery smart unit connector.

    8. Install the No. 2 hybrid battery shield sub-assembly.


    NG
    OK
  4. CHECK BATTERY SMART UNIT (VIB VOLTAGE)

    Note

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 hybrid battery shield sub-assembly Click here.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

      Note

      Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. A005B5ZE02
      Text in Illustration
      *a

      Component with harness connected

      (Battery Smart Unit)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      z24-24 (VIB) - z24-12 (GIB) Power switch on (IG) 4.6 to 5.4 V
    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Install the No. 1 hybrid battery shield sub-assembly.


    NG
    OK
  5. CHECK BATTERY SMART UNIT (BATTERY CURRENT SENSOR OUTPUT VOLTAGE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 hybrid battery shield sub-assembly Click here.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

      Note

      Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    5. A005CPSE02
      Text in Illustration
      *a

      Component with harness connected

      (Battery Smart Unit)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      z24-11 (IB1) - z24-12 (GIB) Power switch on (IG) 2.16 to 2.24 V
      z24-23 (IB0) - z24-12 (GIB) Power switch on (IG) 2.76 to 2.84 V
    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Install the No. 1 hybrid battery shield sub-assembly.


    OK
    NG