BATTERY CURRENT SENSOR INSPECTION
PROCEDURE
CHECK BATTERY CURRENT SENSOR ASSEMBLY
-
*a
Component without harness connected
(Battery Current Sensor Assembly)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
2 (VC5) - 4 (E2)
Always
3 to 10 kΩ
2 (VC5) - 3 (IB)
Below 0.5 kΩ
3 (IB) - 4 (E2)
3 to 10 kΩ
If the result is not as specified, replace the battery current sensor assembly.
-
*a
Component without harness connected
(Battery Current Sensor Assembly)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (THB) - 4 (E2)
Always
1.5 to 2.5 kΩ
If the result is not as specified, replace the battery current sensor assembly.
-