BATTERY CURRENT SENSOR INSPECTION

PROCEDURE

  1. CHECK BATTERY CURRENT SENSOR ASSEMBLY

    1. A192813C03

      *a

      Component without harness connected

      (Battery Current Sensor Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      2 (VC5) - 4 (E2)

      Always

      3 to 10 kΩ

      2 (VC5) - 3 (IB)

      Below 0.5 kΩ

      3 (IB) - 4 (E2)

      3 to 10 kΩ

      If the result is not as specified, replace the battery current sensor assembly.

    2. A192813C08

      *a

      Component without harness connected

      (Battery Current Sensor Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      1 (THB) - 4 (E2)

      Always

      1.5 to 2.5 kΩ

      If the result is not as specified, replace the battery current sensor assembly.