AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM(for Sedan) Headlight Leveling ECU Power Source Circuit
| DTC Code | DTC Name |
|---|---|
| Headlight Leveling ECU Power Source Circuit |
DESCRIPTION
This circuit detects the state of the ignition switch, and sends it to the headlight leveling ECU assembly.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following procedure.
Make sure to perform vehicle information synchronization and initialization after replacing the headlight leveling ECU assembly.
PROCEDURE
READ VALUE USING GTS
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / HL AutoLeveling / Data List.
Read the Data List according to the display on the GTS.
Body Electrical > HL AutoLeveling > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
+B
IG power supply voltage value
0.00 to 19.75 V
11.00 to 14.00 V
-
Body Electrical > HL AutoLeveling > Data List
Tester Display
+B
OK
Normal condition listed above is displayed.
Result
Proceed to
OK
NG
CHECK HARNESS AND CONNECTOR (POWER SOURCE - HEADLIGHT LEVELING ECU ASSEMBLY)
Disconnect the A182 headlight leveling ECU assembly connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
A182-1 (IG) - Body ground
Ignition switch off
Below 1 V
A182-1 (IG) - Body ground
Ignition switch ON
11 to 14 V
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (HEADLIGHT LEVELING ECU ASSEMBLY - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
A182-9 (E1) - Body ground
Always
Below 1 Ω
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR