REAR DOOR LOCK INSPECTION

PROCEDURE

  1. INSPECT REAR DOOR LOCK ASSEMBLY LH (w/o Double Locking System)

    B184440E15
    1. Check the door lock motor operation.

      1. Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.

        OK

        Measurement Condition

        Specified Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 4 (L)

        Unlock

        • If the result is not as specified, replace the door lock assembly.

    2. Check the detection switch.

      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        6 (LSSR) - 9 (E)

        Unlock

        Below 1 Ω

        6 (LSSR) - 9 (E)

        Lock

        10 kΩ or higher

        • If the result is not as specified, replace the door lock assembly.

  2. INSPECT REAR DOOR LOCK ASSEMBLY LH (w/ Double Locking System)

    B144119E11
    1. Check the door lock motor operation.

      1. Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.

        OK

        Measurement Condition

        Specified Condition

        Battery positive (+) → 2 (L)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 2 (L)

        Unlock

        Battery positive (+) → 4 (DL)

        Battery negative (-) → 3 (UNDL)

        Set

        Battery positive (+) → 3 (UNDL)

        Battery negative (-) → 4 (DL)

        Unset

        • If the result is not as specified, replace the door lock assembly.

    2. Check the detection switch.

      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        5 (LSSR) - 6 (E)

        Unlock

        Below 1 Ω

        5 (LSSR) - 6 (E)

        Lock

        10 kΩ or higher

        • If the result is not as specified, replace the door lock assembly.

  3. INSPECT REAR DOOR LOCK ASSEMBLY RH (w/o Double Locking System)

    B184441E16
    1. Check the door lock motor operation.

      1. Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.

        OK

        Measurement Condition

        Specified Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 4 (L)

        Unlock

        • If the result is not as specified, replace the door lock assembly.

    2. Check the detection switch.

      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        6 (LSSR) - 9 (E)

        Unlock

        Below 1 Ω

        6 (LSSR) - 9 (E)

        Lock

        10 kΩ or higher

        • If the result is not as specified, replace the door lock assembly.

  4. INSPECT REAR DOOR LOCK ASSEMBLY RH (w/ Double Locking System)

    B144120E13
    1. Check the door lock motor operation.

      1. Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.

        OK

        Measurement Condition

        Specified Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 3 (UL)

        Lock

        Battery positive (+) → 3 (UL)

        Battery negative (-) → 4 (L)

        Unlock

        Battery positive (+) → 2 (DL)

        Battery negative (-) → 1 (UNDL)

        Set

        Battery positive (+) → 1 (UNDL)

        Battery negative (-) → 2 (DL)

        Unset

        • If the result is not as specified, replace the door lock assembly.

    2. Check the detection switch.

      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        9 (LSSR) - 10 (E)

        Unlock

        Below 1 Ω

        9 (LSSR) - 10 (E)

        Lock

        10 kΩ or higher

        • If the result is not as specified, replace the door lock assembly.