SELECT STROKE SENSOR INSTALLATION
PROCEDURE
INSTALL SELECT STROKE SENSOR
Coat a new O-ring with MP grease and install it to the select stroke sensor.
-
*a
Sensor Arm (Shift and Select Actuator Assembly Side)
*b
Sensor Arm (Select Stroke Sensor Side)
Temporarily install the select stroke sensor with the select stroke sensor side and shift and select actuator assembly side sensor arms in the positions shown in the illustration.
Turn the select stroke sensor clockwise and install it with the 2 screws.
1.3 N*m
13 kgf*cm
12 in.*lbf
Connect the select stroke sensor connector.
INSTALL BATTERY CLAMP SUB-ASSEMBLY
INSTALL BATTERY
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
PERFORM INITIALIZATION AND LEARNING
PERFORM SYNCHRONIZATION POSITION CALIBRATION