| Tester Connection |
Shift Lever Position |
Specified Condition |
| 4 (B) - 5 (L) |
P or N |
Below 1 Ω |
| 4 (B) - 5 (L) |
Not on P or N |
10 kΩ or higher |
| 1 (RL) - 2 (RB) |
R |
Below 1 Ω |
| 1 (RL) - 2 (RB) |
Not on R |
10 kΩ or higher |
| 2 (RB) - 7 (DL) |
D |
Below 1 Ω |
| 2 (RB) - 7 (DL) |
Not on D |
10 kΩ or higher |
| 2 (RB) - 3 (2L) |
2 |
Below 1 Ω |
| 2 (RB) - 3 (2L) |
Not on 2 |
10 kΩ or higher |
| 2 (RB) - 8 (LL) |
L |
Below 1 Ω |
| 2 (RB) - 8 (LL) |
Not on L |
10 kΩ or higher |
|