2AD-FHV FUEL SERVICE DATA

Table 1. Suction Control Valve Assembly

Tester Connection

Condition

Specified Condition

1 - 2

20°C (68°F)

1.9 to 2.3 Ω

Table 2. Fuel Temperature Sensor

Tester Connection

Condition

Specified Condition

1 - 2

20°C (68°F)

2.32 to 2.59 kΩ

1 - 2

80°C (176°F)

0.310 to 0.326 kΩ

Table 3. Fuel Pressure Sensor

Tester Connection

Condition

Specified Condition

5-4

Always

16.4 kΩ or less

2-3

Always

16.4 kΩ or less

6-5

Always

3 kΩ or less

1-2

Always

3 kΩ or less

Table 4. Pressure Discharge Valve

Tester Connection

Condition

Specified Condition

1-2

20°C (68°F)

0.96 to 1.16 Ω

Table 5. Fuel Sender Gauge Assembly

Tester Connection

Condition

Specified Condition

1-2

Float level is F

(upper)

13.5 to 16.5 Ω

1-2

1/2

200.3 to 224.7 Ω

1-2

Float level is E

(lower)

405.5 to 414.5 Ω

Table 6. Fuel Sedimenter Warning Switch

Tester Connection

Condition

Specified Condition

1 - 2

Float upper end position

Below 1 Ω

1 - 2

Float lower end position

10 kΩ or higher