HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A4B-253, P0A4C-513, P0A4D-255

DTC Code DTC Name
P0A4B-253 Generator Position Sensor Circuit
P0A4C-513 Generator Position Sensor Circuit Range / Performance
P0A4D-255 Generator Position Sensor Circuit Low

DESCRIPTION

A resolver is a sensor that is used to detect the position of the magnetic poles the rotor of a motor generator. Knowing the position of the poles is indispensable for ensuring precise control of MG2 and MG1.

Each resolver contains a stator that has an excitation coil and 2 detection coils (S, C). The gap between the stator and rotor changes as the rotor turns because the rotor is oval shaped. An alternating current with a predetermined frequency flows through the excitation coil, and detection coils S and C output alternating currents in accordance with the sensor rotor position.

The inverter with converter assembly (MG ECU) detects the absolute position of the rotor according to the phases of detection coils S and C and the heights of their waveforms. Furthermore, the CPU calculates the amount of change in the position within a predetermined length of time, in order to use the resolver as a speed sensor.

The MG ECU monitors signals output from the motor resolver and detects malfunctions.

B005Y9KE32
DTC No. INF Code DTC Detection Condition Trouble Area
P0A4B 253 Interphase short in the generator resolver circuit
  • Inverter with converter assembly

  • Hybrid vehicle generator assembly

  • Hybrid vehicle motor assembly

  • Wire harness or connector

P0A4C 513 Generator resolver output is out of the normal range
P0A4D 255 Open or short in the generator resolver circuit

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 Click here.

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

Tech Tips


  • If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.

  • After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


    1. Turn the power switch on (IG) and wait for 5 seconds or more.

    2. Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more.

    3. Depress the accelerator pedal of the vehicle with the engine stopped and park (P) selected to start the engine.

    4. Keep the engine running for 5 seconds or more.

    5. Drive the vehicle forward with drive (D) selected for 5 m or more.

    6. Drive the vehicle backward with reverse (R) selected for 5 m or more.

PROCEDURE


  1. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. A005CAR

      Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

    2. Check the connection of the low voltage connector of the inverter with converter assembly.

      OK
      The connector is connected securely and there are no contact problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the D29 inverter with converter assembly connector.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. B005XITE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      D29-11 (GRF) - Body ground Power switch on (IG) Below 1 V
      D29-12 (GRFG) - Body ground Power switch on (IG) Below 1 V
      D29-7 (GSN) - Body ground Power switch on (IG) Below 1 V
      D29-8 (GSNG) - Body ground Power switch on (IG) Below 1 V
      D29-10 (GCS) - Body ground Power switch on (IG) Below 1 V
      D29-9 (GCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Disconnect the cable from the negative (-) auxiliary battery terminal.

    7. Turn the power switch off.

    8. Reconnect the D29 inverter with converter assembly connector.


    NG
    OK
  3. CHECK GENERATOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the D29 inverter with converter assembly connector.

    3. B005XITE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      D29-11 (GRF) - D29-12 (GRFG) Power switch off 7.1 to 21.6 Ω
      D29-7 (GSN) - D29-8 (GSNG) Power switch off 13.7 to 34.5 Ω
      D29-10 (GCS) - D29-9 (GCSG) Power switch off 12.8 to 32.4 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      D29-11 (GRF) or D29-12 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      D29-7 (GSN) or D29-8 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      D29-10 (GCS) or D29-9 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
    4. Reconnect the D29 inverter with converter assembly connector.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the D29 inverter with converter assembly connector.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. B005ZGNE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      D29-1 (MRF) - Body ground Power switch on (IG) Below 1 V
      D29-2 (MRFG) - Body ground Power switch on (IG) Below 1 V
      D29-3 (MSN) - Body ground Power switch on (IG) Below 1 V
      D29-4 (MSNG) - Body ground Power switch on (IG) Below 1 V
      D29-6 (MCS) - Body ground Power switch on (IG) Below 1 V
      D29-5 (MCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Disconnect the cable from the negative (-) auxiliary battery terminal.

    7. Turn the power switch off.

    8. Reconnect the D29 inverter with converter assembly connector.


    NG
    OK
  5. CHECK MOTOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the D29 inverter with converter assembly connector.

    3. B005ZGNE03
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      D29-1 (MRF) - D29-2 (MRFG) Power switch off 7.1 to 21.6 Ω
      D29-3 (MSN) - D29-4 (MSNG) Power switch off 13.7 to 34.5 Ω
      D29-6 (MCS) - D29-5 (MCSG) Power switch off 12.8 to 32.4 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      D29-1 (MRF) or D29-2 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      D29-3 (MSN) or D29-4 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      D29-6 (MCS) or D29-5 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
    4. Reconnect the D29 inverter with converter assembly connector.


    NG
    OK
  6. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. B005Y9J

      Check the connection of the generator resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  7. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. B005Z3L

      Check the connection of the motor resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    OK
    NG
  8. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. B005Y9J

      Check the connection of the generator resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  9. INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR RESOLVER)


    1. B005Y9JN03

      Disconnect the D7 generator resolver connector.

    2. B005YPVC15
      *a

      Component without harness connected

      (Generator Resolver (Hybrid Vehicle Transaxle Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      D7-1(GRF) - D7-5(GRFG) Power switch off 9.5 to 15.5 Ω
      D7-2(GSN) - D7-6(GSNG) Power switch off 15.0 to 27.0 Ω
      D7-3(GCS) - D7-7(GCSG) Power switch off 14.0 to 26.0 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      D7-1 (GRF) - Body ground and other terminals (except D7-5 (GRFG)) Power switch off 1 MΩ or higher
      D7-5 (GRFG) - Body ground and other terminals (except D7-1 (GRF)) Power switch off 1 MΩ or higher
      D7-2 (GSN) - Body ground and other terminals (except D7-6 (GSNG)) Power switch off 1 MΩ or higher
      D7-6 (GSNG) - Body ground and other terminals (except D7-2 (GSN)) Power switch off 1 MΩ or higher
      D7-3 (GCS) - Body ground and other terminals (except D7-7 (GCSG)) Power switch off 1 MΩ or higher
      D7-7 (GCSG) - Body ground and other terminals (except D7-3 (GCS)) Power switch off 1 MΩ or higher

      Tech Tips

      The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

    3. Connect the D7 generator resolver connector.


    OK
    NG
  10. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. B005Z3L

      Check the connection of the motor resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  11. INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR RESOLVER)


    1. B005Z3LN03

      Disconnect the D1 motor resolver connector.

    2. B005ZK4C09
      *a

      Component without harness connected

      (Motor Resolver (Hybrid Vehicle Transaxle Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      D1-3 (MRF) - D1-6 (MRFG) Power switch off 9.5 to 15.5 Ω
      D1-1 (MSN) - D1-4 (MSNG) Power switch off 15.0 to 27.0 Ω
      D1-2 (MCS) - D1-5 (MCSG) Power switch off 14.0 to 26.0 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      D1-3 (MRF) - Body ground and other terminals (except D1-6 (MRFG)) Power switch off 1 MΩ or higher
      D1-6 (MRFG) - Body ground and other terminals (except D1-3 (MRF)) Power switch off 1 MΩ or higher
      D1-1 (MSN) - Body ground and other terminals (except D1-4 (MSNG)) Power switch off 1 MΩ or higher
      D1-4 (MSNG) - Body ground and other terminals (except D1-1 (MSN)) Power switch off 1 MΩ or higher
      D1-2 (MCS) - Body ground and other terminals (except D1-5 (MCSG)) Power switch off 1 MΩ or higher
      D1-5 (MCSG) - Body ground and other terminals (except D1-2 (MCS)) Power switch off 1 MΩ or higher

      Tech Tips

      The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

    3. Connect the D1 motor resolver connector.


    OK
    NG