AIR FUEL RATIO SENSOR(for DPF) INSTALLATION

PROCEDURE

  1. INSTALL AIR FUEL RATIO SENSOR

    1. A273330C01

      *1

      Fulcrum Length

      Using SST, install the air fuel ratio sensor.

      09224-00010

      without SST

      44 N*m

      449 kgf*cm

      32 ft.*lbf

      with SST

      40 N*m

      408 kgf*cm

      30 ft.*lbf

      Tip:
      • Use a torque wrench with a fulcrum length of 300 mm (11.8 in.). When using a torque wrench with afulcrum length that is not 300 mm (11.8 in.), calculate the torque specification for the torque wrench and SST based on the "without SST" torque specification.

      • Make sure SST and the wrench are connected in a straight line.

    2. Install the harness clamp.

  2. INSTALL FRONT EXHAUST PIPE ASSEMBLY

  3. INSPECT FOR EXHAUST GAS LEAK

  4. PERFORM INITIALIZATION