GENERATOR INSTALLATION
PROCEDURE
INSTALL GENERATOR ASSEMBLY
Install the generator assembly with the 3 bolts.
25 N*m
255 kgf*cm
18 ft.*lbf
Note:Be careful that the wire harness of the crankshaft position sensor does not get caught between the cylinder block and generator when installing the generator.
Connect the connector to the generator assembly.
Connect the wire harness to terminal B with the nut.
9.8 N*m
100 kgf*cm
87 in.*lbf
Install the terminal cap.
Connect the wire harness to the generator assembly with the bolt.
7.7 N*m
79 kgf*cm
68 in.*lbf
INSTALL WIRE HARNESS CLAMP BRACKET
Install the wire harness clamp bracket with the bolt.
13 N*m
133 kgf*cm
10 ft.*lbf
Attach the wire harness clamp and connect the sensor connector.
INSTALL FRONT DRIVE SHAFT ASSEMBLY RH
INSTALL FAN AND GENERATOR V BELT
INSTALL NO. 1 ENGINE COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.