WATER PUMP WITH MOTOR INSTALLATION

PROCEDURE


  1. INSTALL INVERTER WATER PUMP ASSEMBLY


    1. Install the inverter water pump assembly and water pump bracket with the 3 bolts.

      Torque:
      6.1 N*m  { 62 kgf*cm, 54 in.*lbf }

      Note

      Do not hold the inverter water pump assembly by the connector terminals when removing or installing it.

    2. A005DUPE03
      Text in Illustration
      *a Front Side
      *b Alignment Mark (Green)
      *c Alignment Mark (Pink)

      Connect the 2 water hoses and connector.

      Note


      • Make sure that the clip is positioned as shown in the illustration.

      • Make sure to align the alignment marks of the hoses with the ribs of the inverter water pump assembly.

      • Do not remove the pieces of cloth from the pipes and disconnected hoses until installation to prevent foreign matter from entering the inverter water pump and cooling system.

  2. INSTALL INVERTER TRAY BRACKET

    Click here

  3. INSTALL INVERTER RESERVE TANK ASSEMBLY

    Click here

  4. INSTALL INVERTER WITH CONVERTER ASSEMBLY

    Click here

  5. ADD COOLANT (for Inverter)

    Click here

  6. INSPECT FOR COOLANT LEAK (for Inverter)

    Click here

  7. INSTALL NO. 1 ENGINE UNDER COVER