ULTRASONIC SENSOR(for Front) INSPECTION

PROCEDURE

  1. INSPECT NO. 1 ULTRASONIC SENSOR

    1. E270770C01

      *a

      Component without harness connected

      (No. 1 Ultrasonic Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      1 (BI) - 5 (EI)

      Always

      10 kΩ or higher

      1 (BI) - 2 (BO)

      Always

      10 kΩ or higher

      3 (SI) - 4 (SO)

      Always

      Below 1 Ω

      5 (EI) - 6 (EO)

      Always

      Below 1 Ω

      If the result is not as specified, replace the No. 1 ultrasonic sensor.