METER / GAUGE SYSTEM, Diagnostic DTC:B1507 and B1508
| DTC Code | DTC Name |
|---|---|
| B1507 | Open in Turn Signal Circuit |
| B1508 | Short in Turn Signal / Hazard Flasher Circuit |
DESCRIPTION
These DTCs are stored when the combination meter assembly detects an open in a turn signal light circuit, a short in a turn signal light circuit, or a short in the hazard warning light circuit.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
Memory |
Note |
|---|---|---|---|---|---|
B1507 |
Open in Turn Signal Circuit |
When IG voltage is 9.5 V or more and the following condition is detected:
|
|
DTC stored |
- |
B1508 |
Short in Turn Signal / Hazard Flasher Circuit |
When IG voltage is 9.5 V or more and the following condition is detected:
|
|
DTC stored |
- |
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the bulbs for this system before performing the following procedure.
PROCEDURE
INSPECT LIGHTS
Inspect the illumination of each turn signal light.
Result
Result
Proceed to
Turn signal lights for one side do not illuminate.
A
Front turn signal light does not illuminate.
B
Rear turn signal light does not illuminate.
C
Side turn signal light does not illuminate.
D
B CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)Click here
C CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)Click here
D CHECK HARNESS AND CONNECTOR (OUTER REAR VIEW MIRROR ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)Click here
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the E45 combination meter assembly connector.
Disconnect the 3D instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Table 1. for LH Tester Connection
Condition
Specified Condition
E45-13 (LL) - 3D-36
Always
Below 1 Ω
Table 2. for RH Tester Connection
Condition
Specified Condition
E45-7 (LR) - 3D-45
Always
Below 1 Ω
Standard Resistance (Check for Short)
Table 3. for LH Tester Connection
Condition
Specified Condition
E45-13 (LL) - Body ground
Always
10 kΩ or higher
Table 4. for RH Tester Connection
Condition
Specified Condition
E45-7 (LR) - Body ground
Always
10 kΩ or higher
Result
Result
Proceed to
NG
A
OK
B
A REPAIR OR REPLACE HARNESS OR CONNECTOR
B INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLYClick here
CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the A69*1 or A72*2 headlight assembly connector.
*1: for LH
*2: for RH
Disconnect the 3A instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Table 5. for LH Tester Connection
Condition
Specified Condition
A69-1 - 3A-36
Always
Below 1 Ω
A69-2 - Body ground
Always
Below 1 Ω
Table 6. for RH Tester Connection
Condition
Specified Condition
A72-1 - 3A-47
Always
Below 1 Ω
A72-2 - Body ground
Always
Below 1 Ω
Standard Resistance (Check for Short)
Table 7. for LH Tester Connection
Condition
Specified Condition
A69-1 - Body ground
Always
10 kΩ or higher
Table 8. for RH Tester Connection
Condition
Specified Condition
A72-1 - Body ground
Always
10 kΩ or higher
Result
Result
Proceed to
NG
A
OK
B
A REPAIR OR REPLACE HARNESS OR CONNECTOR
B INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLYClick here
CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the L3*1 or L4*2 rear combination light assembly connector.
*1: for LH
*2: for RH
Disconnect the 3E instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Table 9. for LH Tester Connection
Condition
Specified Condition
L3-4 (L) - 3E-26
Always
Below 1 Ω
L3-3 (B) - Body ground
Always
Below 1 Ω
Table 10. for RH Tester Connection
Condition
Specified Condition
L4-4 (L) - 3E-33
Always
Below 1 Ω
L4-3 (B) - Body ground
Always
Below 1 Ω
Standard Resistance (Check for Short)
Table 11. for LH Tester Connection
Condition
Specified Condition
L3-4 (L) - Body ground
Always
10 kΩ or higher
Table 12. for RH Tester Connection
Condition
Specified Condition
L4-4 (L) - Body ground
Always
10 kΩ or higher
Result
Result
Proceed to
NG
A
OK
B
A REPAIR OR REPLACE HARNESS OR CONNECTOR
B INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLYClick here
CHECK HARNESS AND CONNECTOR (OUTER REAR VIEW MIRROR ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
Disconnect the H8*1 or G8*2 outer rear view mirror assembly connector.
*1: for LH
*2: for RH
Disconnect the 3D instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Table 13. for LH Tester Connection
Condition
Specified Condition
H8-1 (B) - 3D-37
Always
Below 1 Ω
H8-2 (E) - Body ground
Always
Below 1 Ω
Table 14. for RH Tester Connection
Condition
Specified Condition
G8-1 (B) - 3D-46
Always
Below 1 Ω
G8-2 (E) - Body ground
Always
Below 1 Ω
Standard Resistance (Check for Short)
Table 15. for LH Tester Connection
Condition
Specified Condition
H8-1 (B) - Body ground
Always
10 kΩ or higher
Table 16. for RH Tester Connection
Condition
Specified Condition
G8-1 (B) - Body ground
Always
10 kΩ or higher
Result
Result
Proceed to
NG
A
OK
B
A REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
for LHD:Click here
for RHD:Click here
*a
Component without harness connected
(Instrument Panel Junction Block Assembly)
-
-
Front turn signal light
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 17. for LH Tester Connection
Condition
Specified Condition
3D-36 - 3A-36
Always
Below 1 Ω
Table 18. for RH Tester Connection
Condition
Specified Condition
3D-45 - 3A-47
Always
Below 1 Ω
Rear turn signal light
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 19. for LH Tester Connection
Condition
Specified Condition
3D-36 - 3E-26
Always
Below 1 Ω
Table 20. for RH Tester Connection
Condition
Specified Condition
3D-45 - 3E-33
Always
Below 1 Ω
Side turn signal light
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 21. for LH Tester Connection
Condition
Specified Condition
3D-36 - 3D-37
Always
Below 1 Ω
Table 22. for RH Tester Connection
Condition
Specified Condition
3D-45 - 3D-46
Always
Below 1 Ω
Result
Proceed to
OK
NG