GENERATOR (for DENSO Made) REMOVAL


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  2. REMOVE AIR CLEANER ASSEMBLY

    A01DWMDE02

    1. Disconnect the MAF meter connector and remove the clamp.

    2. Loosen the hose clamp of the compressor inlet elbow.

    3. Remove the 2 bolts and air cleaner.

  3. REMOVE FAN AND GENERATOR V BELT


    1. A01E0B4E01

      Using the pulley set bolt of the tensioner, rotate the tensioner pulley clockwise to loosen the belt's tension. Then remove the V belt.

  4. REMOVE GENERATOR ASSEMBLY

    A01DXLF

    1. Remove the nut and generator wire.

    2. Disconnect the generator connector.

    3. Remove the 2 bolts and generator.