MULTI-MODE MANUAL TRANSAXLE SYSTEM Starter Signal Circuit
| DTC Code | DTC Name |
|---|---|
| Starter Signal Circuit |
DESCRIPTION
Engine starting control (w/ Entry and Start System)
In this vehicle, the ST (starter) relay that supplies power to the starter motor is operated by the cranking holding function of the certification ECU. When the appropriate vehicle conditions are satisfied, the brake pedal is depressed and the transaxle gear is in neutral, the engine can be cranked.
If the brake pedal is not depressed or the transaxle gear is not in neutral, the engine cannot be cranked.
During cranking, the ST (starter) relay operation signal (STA signal) is input into the STA terminal of the TCM, and is used to control the multi-mode manual transaxle system.
Engine starting control (w/o Entry and Start System)
When the ignition switch is turned to ON and the brake pedal is depressed, the TCM turns on the shift lock solenoid in order to release shift lock.
When the shift lever is in N, the TCM detects that the shift lever is in N using the shift position sensor.
When the engine is started, the start signal is sent to the TCM through the neutral position switch. When the TCM receives this signal, the ST (starter) relay is turned on to cause the engine start.
WIRING DIAGRAM
Refer to DTC P0617.
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
READ VALUE USING GTS (STA SWITCH SIGNAL)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Multi-Mode M/T / Data List / STA Switch Signal.
Read the Data List according to the display on the GTS.
Powertrain > Multi-Mode M/T > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
STA Switch Signal
STA signal
OFF or ON
ON: Cranking
-
Powertrain > Multi-Mode M/T > Data List
Tester Display
STA Switch Signal
OK
ON is displayed in the Data List when cranking.
Result
Proceed to
OK
NG
CHECK ST RELAY (POWER SOURCE)
-
*1
NO. 1 Engine Room Relay Block
*2
ST Relay (Starter Relay)
Remove the ST relay from the No. 1 engine room relay block.
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
ST relay terminal 2 - Body ground
Cranking
11 to 14 V
Result
Result
Proceed to
OK
A
NG (w/o Entry and Start System)
B
NG (w/ Entry and Start System)
C
B CHECK HARNESS AND CONNECTOR (ST RELAY - TCM)Click here
C CHECK HARNESS AND CONNECTOR (ST RELAY - NEUTRAL POSITION SWITCH)Click here
-
INSPECT ST RELAY (STARTER RELAY)
Inspect the ST relay.
Result
Proceed to
OK
NG
NG REPLACE ST RELAY (STARTER RELAY)
CHECK HARNESS AND CONNECTOR (ST RELAY - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
ST relay terminal 1 - Body ground
Always
Below 1 Ω
Result
Proceed to
OK
NG
OK REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - TCM)
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (ST RELAY - TCM)
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
ST relay terminal 2 - A27-4 (STRL)
Always
Below 1 Ω
ST relay terminal 2 - A27-6 (STA)
Always
Below 1 Ω
ST relay terminal 2 - Body ground
Always
10 kΩ or higher
A27-6 (STA) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK TCM (TMN VOLTAGE)
-
*a
Front view of wire harness connector
(to TCM)
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
A27-3 (TMN) - Body ground
Engine cranking
11 to 14 V
Result
Proceed to
OK
NG
-
CHECK HARNESS AND CONNECTOR (TCM - NEUTRAL POSITION SWITCH)
Disconnect the neutral position switch connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
A27-3 (TMN) - A44-1 (TME)
Always
Below 1 Ω
A27-3 (TMN) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT NEUTRAL POSITION SWITCH
Inspect the neutral position switch.
Result
Proceed to
OK
NG
CHECK HARNESS AND CONNECTOR (IGNITION OR STARTER SWITCH ASSEMBLY - NEUTRAL POSITION SWITCH)
Disconnect the neutral position switch connector.
Disconnect the ignition or starter switch assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
E21-7 (ST2) - A44-2 (TMN)
Always
Below 1 Ω
E21-7 (ST2) or A44-2 (TMN) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT IGNITION OR STARTER SWITCH ASSEMBLY
Inspect the ignition or starter switch assembly.
Result
Proceed to
OK
NG
OK REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY - IGNITION OR STARTER SWITCH ASSEMBLY)
CHECK HARNESS AND CONNECTOR (ST RELAY - NEUTRAL POSITION SWITCH)
Disconnect the neutral position switch assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
ST relay terminal 2 - A44-1 (TME)
Always
Below 1 Ω
ST relay terminal 2 - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (ST RELAY - TCM)
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
ST relay terminal 2 - A27-6 (STA)
Always
Below 1 Ω
ST relay terminal 2 - Body ground
Always
10 kΩ or higher
A27-6 (STA) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (ST RELAY - CERTIFICATION ECU)
Disconnect the certification ECU connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
ST relay terminal 2 - E50-37 (STA)
Always
Below 1 Ω
ST relay terminal 2 - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT NEUTRAL POSITION SWITCH
Inspect the neutral position switch.
Result
Proceed to
OK
NG
CHECK HARNESS AND CONNECTOR (NEUTRAL POSITION SWITCH - CERTIFICATION ECU (SMART KEY ECU ASSEMBLY))
Disconnect the certification ECU (smart key ECU assembly) connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
A44-2 (TMN) - E49-5 (STAR)
Always
Below 1 Ω
A44-2 (TMN) - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR