| P050031 |
Vehicle Speed Sensor "A" No Signal |
Comes on |
DTC stored |
SAE: P0500 |
Click here
|
| P056014 |
System Voltage Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P0562 |
Click here
|
| P061512 |
Starter Relay Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P0617 |
Click here
|
| P070312 |
Brake Switch "B" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P0724 |
Click here
|
| P071000 |
Transmission Fluid Temperature Sensor "A" Circuit Range/Performance |
Comes on |
DTC stored |
SAE: P0711 |
Click here
|
| P071011 |
Transmission Fluid Temperature Sensor "A" Circuit Short To Ground |
Comes on |
DTC stored |
SAE: P0712 |
Click here
|
| P071015 |
Transmission Fluid Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on |
DTC stored |
SAE: P0713 |
Click here
|
| P071512 |
Input/Turbine Speed Sensor "A" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P07C0 |
Click here
|
| P071514 |
Input/Turbine Speed Sensor "A" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P07BF |
Click here
|
| P071531 |
Input/Turbine Speed Sensor "A" No Signal |
Comes on |
DTC stored |
SAE: P0717 |
Click here
|
| P072012 |
Output Speed Sensor Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P077D |
Click here
|
| P072014 |
Output Speed Sensor Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P077C |
Click here
|
| P072031 |
Output Speed Sensor No Signal |
Comes on |
DTC stored |
SAE: P0722 |
Click here
|
| P074011 |
Torque Converter Clutch Circuit Short to Ground |
Comes on |
DTC stored |
SAE: P2769 |
Click here
|
| P074015 |
Torque Converter Clutch Circuit Short to Battery or Open |
Comes on |
DTC stored |
SAE: P2770 |
Click here
|
| P07407E |
Torque Converter Clutch Actuator Stuck On |
Comes on |
DTC stored |
SAE: P0741 |
Click here
|
| P074512 |
Pressure Control Solenoid "A" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P0963 |
Click here
|
| P074514 |
Pressure Control Solenoid "A" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P0962 |
Click here
|
| P07457F |
Pressure Control Solenoid "A" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P0746 |
Click here
|
| P076A11 |
Shift Solenoid "H" Control Circuit Short to Ground |
Comes on |
DTC stored |
SAE: P099E |
Click here
|
| P076A15 |
Shift Solenoid "H" Control Circuit Short to Battery or Open |
Comes on |
DTC stored |
SAE: P099F |
Click here
|
| P076A71 |
Shift Solenoid "H" Control Actuator Stuck |
Comes on |
DTC stored |
SAE: P076B |
Click here
|
| P077011 |
Shift Solenoid "E" Circuit Short to Ground |
Comes on |
DTC stored |
SAE: P0985 |
Click here
|
| P077015 |
Shift Solenoid "E" Circuit Short to Battery or Open |
Comes on |
DTC stored |
SAE: P0986 |
Click here
|
| P07707E |
Shift Solenoid "E" Actuator Stuck On |
Comes on |
DTC stored |
SAE: P0772 |
Click here
|
| P07707F |
Shift Solenoid "E" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P0771 |
Click here
|
| P077512 |
Pressure Control Solenoid "B" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P0967 |
Click here
|
| P077514 |
Pressure Control Solenoid "B" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P0966 |
Click here
|
| P07757F |
Pressure Control Solenoid "B" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P0776 |
Click here
|
| P079512 |
Pressure Control Solenoid "C" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P0971 |
Click here
|
| P079514 |
Pressure Control Solenoid "C" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P0970 |
Click here
|
| P07957F |
Pressure Control Solenoid "C" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P0796 |
Click here
|
| P08BA12 |
Pressure Control Solenoid "L" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P08C2 |
Click here
|
| P08BA14 |
Pressure Control Solenoid "L" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P08C1 |
Click here
|
| P08BA7F |
Pressure Control Solenoid "L" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P08BB |
Click here
|
| P08CC11 |
Shift Solenoid "J" Control Circuit Short to Ground |
Comes on |
DTC stored |
SAE: P08D2 |
Click here
|
| P08CC15 |
Shift Solenoid "J" Control Circuit Short to Battery or Open |
Comes on |
DTC stored |
SAE: P08D3 |
Click here
|
| P08CC7E |
Shift Solenoid "J" Control Actuator Stuck On |
Comes on |
DTC stored |
SAE: P08CE |
Click here
|
| P08CC7F |
Shift Solenoid "J" Control Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P08CD |
Click here
|
| P08D511 |
Shift Solenoid "K" Control Circuit Short to Ground |
Comes on |
DTC stored |
SAE: P08DB |
Click here
|
| P08D515 |
Shift Solenoid "K" Control Circuit Short to Battery or Open |
Comes on |
DTC stored |
SAE: P08DC |
Click here
|
| P08D57E |
Shift Solenoid "K" Control Actuator Stuck On |
Comes on |
DTC stored |
SAE: P08D7 |
Click here
|
| P08D57F |
Shift Solenoid "K" Control Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P08D6 |
Click here
|
| P271312 |
Pressure Control Solenoid "D" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P2721 |
Click here
|
| P271314 |
Pressure Control Solenoid "D" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P2720 |
Click here
|
| P27137F |
Pressure Control Solenoid "D" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P2714 |
Click here
|
| P275612 |
Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P2763 |
Click here
|
| P275614 |
Torque Converter Clutch Pressure Control Solenoid Control Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P2764 |
Click here
|
| P27567F |
Torque Converter Clutch Pressure Control Solenoid Control Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P2757 |
Click here
|
| P280712 |
Pressure Control Solenoid "G" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P2815 |
Click here
|
| P280714 |
Pressure Control Solenoid "G" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P2814 |
Click here
|
| P28077F |
Pressure Control Solenoid "G" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P2808 |
Click here
|
| P281612 |
Pressure Control Solenoid "H" Circuit Short to Battery |
Comes on |
DTC stored |
SAE: P281E |
Click here
|
| P281614 |
Pressure Control Solenoid "H" Circuit Short to Ground or Open |
Comes on |
DTC stored |
SAE: P281D |
Click here
|
| P28167F |
Pressure Control Solenoid "H" Actuator Stuck Off |
Comes on |
DTC stored |
SAE: P2817 |
Click here
|
| U010087 |
Lost Communication with ECM/PCM "A" Missing Message |
Comes on |
DTC stored |
SAE: U0100 |
Click here
|
| U110387 |
Lost Communication with Stop and Start Control Module Missing Message |
Does not come on |
DTC stored |
SAE: U1103 |
Click here
|