AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) IG Power Source Circuit

DESCRIPTION

The main power source is supplied to the air conditioning amplifier assembly when the ignition switch is turned to ON. The power source is used for operating the air conditioning amplifier assembly, servo motor, etc.

WIRING DIAGRAM

A004S2SE04
*a from IG1 Relay
*b Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Tech Tips

Start the engine before inspection. Check the relays, fuses and battery if the engine does not start.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BATTERY AND BODY GROUND)

    A004N6OE01
    Text in Illustration
    *1

    Rear view of wire harness connector

    (to Air Conditioning Amplifier Assembly)


    1. Disconnect the D101 amplifier connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      D101-1 (IG+) - Body ground Ignition switch off Below 1 V
      Ignition switch ON 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D101-14 (GND) - Body ground Always Below 1 Ω

    OK
    NG