AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST


  1. DATA LIST

    Tech Tips

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Turn the power switch off.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

    4. Turn the GTS on.

    5. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    6. Check the value(s) by referring to the table below.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor

      Room temperature sensor (cooler thermistor) /

      Min.: -6.50°C (20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual cabin temperature displayed -
      Ambient Temp Sensor

      Ambient temperature sensor (thermistor assembly) /

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed -
      Adjusted Ambient Temp

      Adjusted ambient temperature /

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor

      Evaporator temperature sensor (No. 1 cooler thermistor) /

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed -
      Evaporator Target Temp

      Evaporator target temperature /

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed -
      Solar Sensor (D Side)

      Solar sensor (automatic light control sensor) /

      Min.: 0

      Max.: 255

      Solar sensor value increases as brightness increases -
      Engine Coolant Temp

      Engine coolant temperature sensor /

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Set Temperature (D Side)

      Set temperature /

      Min.: MAX COLD

      Max.: MAX HOT

      Actual set temperature displayed -
      Blower Motor Speed Level

      Blower motor speed level /

      Min.: 0

      Max.: 31

      Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
      Regulator Pressure Sensor

      Air conditioner pressure sensor /

      Min.: -0.4566 MPaG

      Max.: 3.2943 MPaG

      Actual regulator pressure displayed -
      Air Mix Servo Targ Pulse(D)

      No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse /

      Min.: 0

      Max.: 255

      MAX. COLD: 6 (pulse)

      MAX. HOT: 93 (pulse)

      -
      Air Mix Servo Actual Pulse(D)

      No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse /

      Min.: 0

      Max.: 255

      MAX. COLD: 6 (pulse)

      MAX. HOT: 93 (pulse)

      -
      Air Outlet Servo Pulse (D)

      No. 2 air conditioning radiator damper servo sub-assembly (air outlet) target pulse /

      Min.: 0

      Max.: 255

      FACE: 47 (pulse)

      B/L: 37 (pulse)

      FOOT: 17 to 23 (pulse)

      FOOT/DEF: 9 (pulse)

      DEF: 5 (pulse)

      -
      Air Outlet Servo Actu Pulse (D)

      No. 2 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse /

      Min.: 0

      Max.: 255

      FACE: 47 (pulse)

      B/L: 37 (pulse)

      FOOT: 17 to 23 (pulse)

      FOOT/DEF: 9 (pulse)

      DEF: 5 (pulse)

      -
      Air Inlet Damper Targ Pulse

      No. 1 blower damper servo sub-assembly (air inlet) target pulse /

      Min.: 0

      Max.: 255


        for LHD:

      • RECIRCULATION: 19 (pulse)

      • FRESH: 7 (pulse)


        for RHD:

      • RECIRCULATION: 7 (pulse)

      • FRESH: 25 (pulse)

      -
      Air Inlet Damper Actual Pulse

      No. 1 blower damper servo sub-assembly (air inlet) actual pulse /

      Min.: 0

      Max.: 255


        for LHD:

      • RECIRCULATION: 19 (pulse)

      • FRESH: 7 (pulse)


        for RHD:

      • RECIRCULATION: 7 (pulse)

      • FRESH: 25 (pulse)

      -
      Electric Heater Count*1

      Maximum heater operation level /

      Min.: 0

      Max.: 3

      Maximum possible operation level of quick heater assembly (PTC heater) displayed -
      Electric Heater Active Level*1

      Actual heater operation level /

      Min.: 0

      Max.: 3

      Actual operation level of quick heater assembly (PTC heater) displayed -
      Compressor Speed

      Compressor speed /

      Min.: 0 rpm

      Max.: 65535 rpm

      Actual compressor speed in range between 0 rpm and 7500 rpm displayed -
      Compressor Target Speed

      Compressor target speed /

      Min.: 0 rpm

      Max.: 65535 rpm

      Target compressor speed in range between 0 rpm and 7500 rpm displayed -
      Shift Set Temperature Shift set temperature / 2C decr, 1C decr, Normal, 1C incr or 2C incr Customized value displayed -
      Air Inlet Mode Air inlet mode / Auto or Manual Customized value displayed -
      Noise and Vibration Reduction Noise and vibration reduction / ON or OFF Customized value displayed -
      ECO MODE Cancel ECO MODE cancel / ON or OFF Customized value displayed -
      ECO Switch

      ECO switch /

      OFF or ON

      ECO mode switch operated: ON

      (when switch is pressed)

      -

      ECO mode switch not operated: OFF

      (when switch is not pressed)

      Foot/DEF Auto Mode Foot/DEF auto mode / ON or OFF Customized value displayed -
      Foot/DEF Auto Blow Up Foot/DEF auto blow up / ON or OFF Customized value displayed -
      Ambient Temperature Shift Ambient temperature shift / 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr or 3C incr Customized value displayed -
      Compressor Drive Check

      Compressor drive check /

      OK or NG

      NG: Compressor does not drive

      OK: Compressor drives

      -
      Number of Trouble Codes

      Number of trouble codes /

      Min.: 0

      Max.: 255

      Number of DTCs displayed -

      • *1: w/ Quick Heater Assembly

  2. ACTIVE TEST

    Tech Tips

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Turn the power switch off.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

    4. Turn the GTS on.

    5. Enter the following menus:


      1. for Air Conditioner: Body Electrical / Air Conditioner / Active Test.

      2. for Engine and ECT: Powertrain / Engine and ECT / Active Test.

    6. Check the operation by referring to the table below.

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
      Compressor Target Speed Compressor target speed Min.: 0, Max.: 7500 -
      Defogger Relay (Rear) Defogger relay OFF, ON -
      Water Pump Water pump relay OFF, ON -
      Electrical Fan Electrical fan OFF, ON -
      Heater Active Level*1 Quick heater assembly Min.: 0, Max.: 3 -
      Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse Min.: 0, Max.: 255 Operates between 6 to 93 pulses
      Air Outlet Servo Pulse (D) No. 2 air conditioning radiator damper servo sub-assembly (air outlet) pulse Min.: 0, Max.: 255 Operates between 5 to 47 pulses
      Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly (air inlet) pulse Min.: 0, Max.: 255

        for LHD:

      • Operates between 7 to 19 pulses


        for RHD:

      • Operates between 7 to 25 pulses

      *1: w/ Quick Heater Assembly

      Engine and ETC
      Tester Display Test Part Control Range Diagnostic Note
      Control the Electric Cooling Fan Electric cooling fan OFF, ON -